Plan Review Details - Project E10100014
Plan Review Stops For Project E10100014
Review Stop ENG-A ENGINEERING FORMAL REVIEW
Rev No 1 Status P Date 10-25-2010 Cont ID  
Sent By mgonzale Date 10-25-2010 Time   Rev Time 3.00
Received By mgonzale Date 10-25-2010 Time   Sent To  
Notes
2010-10-25 12:21:16PASSED WITH PROVISO:
  
 THE PALM BEACH COUNTY HEALTH DEPARTMENT'S REQUIREMENTS
 FOR DESIGN, CONSTRUCTION, CLEARANCE AND SEPARATION OF
 WATER, SEWER AND OTHER FACILITIES SHALL BE STRICTLY
 OBSERVED.
  
 ALL WORK SHALL BE PERFORMED IN A SAFE AND PROFESSIONAL
 MANNER. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE
 LAWS AND REGULATIONS REGARDING THE SAFETY OF PERSONS
 AND PROPERTY. THEREFORE, IT WILL BE THE CONTRACTOR
 RESPONSABILITY TO NOTIFY AFFECTED TENANTS AND RESIDENTS
 48 HOURS PRIOR TO COMMENCING WORK.
  
 CONTRACTOR SHALL SUPPLY ALL NECESSARY EQUIPMENT TO
 PROVIDE A SAFE WORK AREA. CONTRACTOR SHALL SUPPLY ALL
 NECESSARY EQUIPMENT TO AVOID ANY MATERIAL SPILL.
  
 MAINTENANCE OF TRAFFIC SHALL BE USED WHEN BLOCKING
 ROADWAY.
  
 PROJECTS HANDLING OR GENERATING ANY TOXIC/HAZARDOUS
 SUBSTANCES SHALL BE IDENTIFIED AND THEIR METHODS OF
 PRETREATMENT SPECIFIED. PRETREATMENT PROCEDURES SHALL
 BE ACCEPTABLE TO CITY OF WPB AND SHALL CONFORM TO ALL
 STATE AND FEDERAL REGULATIONS. AFFECTED BUSINESSES
 INCLUDE, BUT ARE NOT LIMITED TO, ALL COMMERCIAL AND
 INDUSTRIAL USERS OF AUTHORITY FACILITIES FOR WHICH
 FEDERAL AND/OR STATE PRETREATMENT STANDARDS HAVE BEEN
 PROMULGATED. THIS INCLUDES BUSINESSES SUCH AS PLATING
 AND METAL FINISHING OPERATIONS. BUSINESSES THAT QUALIFY
 AS SIGNIFICANT USERS WILL BE REQUIRED TO OBTAIN A
 WASTEWATER DISCHARGE PERMIT IN ACCORDANCE WITH CITY'S
 WASTEWATER PRETREATMENT PROGRAM.
  
 ALL MAINS, INCLUDING FITTINGS, SHALL BE EASILY
 IDENTIFIABLE AS TO THEIR CONTENTS AND SHALL BE COLOR
 CODED OR MARKED USING THE UNIVERSAL COLOR CODE OF BLUE
 FOR WATER, GREEN FOR SEWER AND LAVENDER FOR RECLAIMED.
  
 PROPOSED CONFLICT MANHOLE ELEVATION SHOULD BE LESS THAN
 THAT OF FFE: EXISTING BUILDINGS WHICH HAVE PLUMBING
 DRAIN OUTLETS AT AN ELEVATION 12" OR LESS ABOVE THE
 GROUND SURFACE OF THE NEXT UPSTREAM MANHOLE, WHERE THE
 ELEVATION OF ANY FLOOR IS AT OR BELOW THE INVERT OF THE
 ADJACENT CITY SANITARY SEWER MAIN OR IS LESS THAN 12"
 ABOVE THE GROUND SURFACE OF THE NEXT UPSTREAM MANHOLE,
 OR WHERE A CONDITION EXISTS WHERE A PLUG IN THE CITY
 SANITARY SEWER MAIN WILL CAUSE THE HYDRAULIC GRADIENT
 TO RISE ABOVE THE LOWEST FLOOR LEVEL.
  
 A CLEAN-OUT IS REQUIRED AT EVERY BEND ON SEWER LINE.
 (NO CLEAN-OUTS ARE SHOWN ON PLAN). PROVIDE ON AS-BUILT.
  
 RECORD DRAWING REQUIREMENTS:
 WATER / SANITARY / STORM PIPE CROSSINGS AND
 SEPARATIONS:
 * SEPARATION POINT / CONFLICT CROSSING: VERTICAL OR
 HORIZONTAL DISTANCE PROXIMITY BETWEEN TWO DIFFERENT
 UTILITY
 SYSTEMS. CLEARLY IDENTIFY AND SEQUENTIALLY NUMBER (#)
 THE LOCATION OF ALL SEPARATION POINTS OR CONFLICT
 CROSSINGS IN
 CONFORMANCE WITH PALM BEACH COUNTY HEALTH DEPARTMENT
 UTILITY SEPARATION GUIDELINES.
 * PROVIDE A UTILITY SEPARATION CHART. CHART SHALL
 INCLUDE SEQUENTIAL NUMBERING, TYPE OF UTILITY (WATER,
 SEWER,
 STORMWATER, ETC), PIPE SIZE, PIPE TYPE, LABEL UPPER
 PIPE AND LOWER PIPE (NOT REQUIRED FOR HORIZONTAL
 SEPARATION),
 DISTANCE BETWEEN BOTTOM OF UPPER PIPE AND CROWN OF
 LOWER PIPE.
 * CONFLICT STORM/WATER / SANITARY STRUCTURES:
 1PROVIDE VERTICAL DISTANCE OF TOP AND BOTTOM OF CASING.
 2 PROVIDE TYPE OF CASING MATERIAL.
 3 PROVIDE TYPE OF TRANSMISSION PIPE MATERIAL.
 * CASINGS:
 1 PROVIDE VERTICAL DISTANCE OF TOP AND BOTTOM OF
 CASING.
 2 PROVIDE TYPE OF CASING MATERIAL.
 3 PROVIDE INFORMATION ON TOTAL LAY LENGTH AND THE
 LOCATION OF ANY VENTS OR TAPS.
  
 MANUEL JULIAN GONZALEZ
 ENGINEERING PROJECT COORDINATOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 MOBILE: (561) 644-7301
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop ENG-D ENGINEERING DEFICIENCY REVIEW
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop ENG-E ENGINEERING ENVR. MIT. REVIEW
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop ENG-F ENGINEERING FINAL DRAWING REV
Rev No 1 Status P Date 11-03-2010 Cont ID  
Sent By mgonzale Date 11-03-2010 Time   Rev Time 1.00
Received By mgonzale Date 11-03-2010 Time   Sent To  
Notes
2010-11-03 16:19:41PASSED:
 INFORMATION ON SEWER AS PERO JMCDERMOTT FINAL REPORT
 REPAIR WAS ACCOMPLISHED WITH FERNCO AND SLEEVE THRU
 SANITARY MAONHOLE.
 9'6" DIMENSIONS TOWARDS LAKE WITH A 26" DEPTH ON
 PIPE/SLEEVE
 8'6" DIMENSION TOWARDS BUILDING WITH A 27 1/2" DEPTH ON
 PIPE/SLEEVE
 INFORMATION PROVIDED BY RK CONTRACTORS.
 PROJECT IS CONSIDERED APPROVED AND CLOSED.
 11/03/2010
 MANUEL JULIAN GONZALEZ
 ENGINEERING PROJECT COORDINATOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 MOBILE: (561) 644-7301
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
  

Review Stop ENG-M ENGINEERING MODIFICATION REV
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop ENG-P ENGINEERING PLANNING REVIEW
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop ENG-T ENGINEERING TRAFFIC STUDY REV
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

  Print


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved