| Plan Review Notes For Permit 99122041 |
| Permit Number |
99122041 |
|
| Review Stop |
R |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2001-01-08 00:00:00 | APPROVED WITH PROVISO: | | | 1-PROVIDE COMPLETE BATHROOM WITH A DOOR | | | HAVING A MINIMUM OF 29" CLEAR OPENING. | | | SECTION 11 OF FLORIDA ACCESSIBILITY | | | CODE FOR BUILDING CONSTRUCTION,1997. | | | 2-PROVIDE PRODUCT APPROVAL FOR SLIDING | | | WINDOWS. | | | RE-SUBMIT OTHER PRODUCT APPROVALS. SEE | | | COMMENTS. | | | 3-REVISE SIZE OF EGRESS WINDOW AT | | | BEDROOM #3. MINIMUM NET CLEAR OPENING | | | TO BE 5.7 SQ. FT. SEC. 1005.4 SBC/1997 | | | 4-PROVIDE COMPLETE FRAMING DETAILS FOR | | | ARCHED OPENINGS. | | | 5-SEE ALL COMMENTS ON PLANS AND REVISE/ | | | UPDATE ALL DRAWINGS AS REQUIRED. | | | RE-SUBMIT PRIOR TO INSPECTIONS. | | | 6-ATTIC ACCESS TO BE 22" X 36" MIN. | | | SECTION 2309.6 SBC 1997. | | | 7-PROVIDE DRAFSTOPPING AT SECOND FLOOR | | | FRAMING PLAN. SEE SEC.2305.2 SBC/1997. | | | 8-COMPLY WITH PROVISOS BY OTHER TRADES. | | | 9-PROVIDE PRODUCT APPROVAL FOR FLAT | | | ROOF SYSTEM. | | | 10-PROVIDE THE DESIGN PRESSURES AT ALL | | | EXTERIOR OPENINGS AS PER SECTION 1606 | | | SBC 1997. |
|