Text |
| 2001-01-08 00:00:00 | SHT.1-MAX.HEIGHT TO BOTTOM OF WOOD | | | BLOCKING FOR SIDE OF TOILET SHALL BE 32" | | | (PLANS SHOW 32" MIN.)PER FHA REQ.6,FIG. | | | #3. | | | | | | SUPPLY WOOD BLOCKING DETAILS FOR SHOWER. | | | COMPLY W/FHA REQ.#6,FIG.#5. | | | | | | CLEARLY INDICATE ON THE PLANS WHICH | | | DESIGN SPECIFICATION(A OR B)OF THE FAIR | | | HOUSING ACT IS BEING UTILIZED. | | | | | | BATHROOM #2,UNIT MDL-1409,LENGTH OF THE | | | BATHROOM DOESN'T HAVE THE DIMENSION | | | REQUIRED FOR TYPE "A" BATH WHEN | | | APPROACHED FROM THE BEDROOM. | | | | | | THE LOCATION OF THE PLUMBING FIXTURES ON | | | THE SANITARY RISER DOESN'T MATCH THE | | | ARCH.FLOOR PLAN.COUNTYWIDE AMENDMENTS TO | | | SPC SEC.104.2.1. |
|