| Plan Review Notes For Permit 99121713 |
| Permit Number |
99121713 |
|
| Review Stop |
R |
| Sequence Number |
3 |
|
| Notes |
| Date |
Text |
| 2001-01-12 00:00:00 | TRUSS DRAWINGS CHECKLIST: | | | 1-TRUSS DRAWINGS GENERAL DETAILS AND | | | SPECIFICATIONS PACKAGE NEED TO BE | | | COORDINATED AND UPDATED. THERE ARE | | | DETAILS AND SPECIFICATIONS THAT ARE | | | TOO OLD AND REFERENCING OLD CODES. | | | -ENGINEER IS SIGNING AND SEALING | | | DOCUMENTS THAT HAVE THE NAME OF | | | ANOTHER ENGINEER. | | | -ENGINEER TO FOLLOW ALL REQUIREMENTS | | | OF CHAPTER 471 FLORIDA STATUTES WHEN | | | SUBMITTING DOCUMENTS FOR PUBLIC | | | RECORD3-SUPPORT REPORT INDICATES THAT | | | TRUSSES | | | WERE DESIGNED USING SBC 1991. CITY HAS | | | ADOPTED SBC 1997. | | | | | | | | | | | | | | | IF YOU HAVE ANY QUESTIONS, CALL JULIO | | | GOMEZ AT 659-8096 EXT. 8232. |
|