Plan Review Notes
Plan Review Notes For Permit 99121671
Permit Number 99121671
Review Stop R
Sequence Number 2
Notes
Date Text
2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE A8. PROVIDE ELEVATION
 CERTIFICATE.
 2-REVISE SHEET A-1 AND A-2: DRYER IS NOT
 ALLOW TO VENT THRU THE WALL AT ZERO
 LOT LINE WALL. TABLE 600 SBC 1997.
 3-SEE COMMENTS ON PLANS AND REVISE/
 UPDATE DRAWINGS AS REQUIRED.
 4-REAR ELEVATION BY FAMILY AREA TO HAVE
 THE 34 SH WINDOW OPTION IN ORDER TO
 MEET THE TABLE 600 REQUIREMENTS.
 5-SEE PROVISOS BY OTHER TRADES.
 6-RE-SUBMIT GARAGE DOOR PRODUCT APPROVAL
 DRAWINGS DON'T MATCH PRODUCT APPROVAL.
 WHY FINAL PRODUCT APPROVAL BY SBCCI
 DOEN'T HAVE A NUMBER ASSIGNED?.
 7-STORM PANELS:
 -INSTALLATION SCHEDULE AND KEY PLAN
 DON'T MATCH PLANS. REVISE AS REQUIRED
 AND COMPLETE ALL THE INFORMATION AS
 REQUESTED ON CITY SAMPLE INSTALLATION
 SCHEDULE ATTACHED.
 -SEE NOTE #4 ON SHEET 3 OF 5 OF STORM
 PANELS DRAWINGS. INSTALLATION SCHED.
 CALLS FOR 33" STORM PANELS AND THIS
 NOTE CALLS FOR A 40" MIN. STORM PANEL.
 REVISE AS REQUIRED.
 8-ENTRY DOOR:
 -CLEARLY SPECIFY FASTENERS TO BE USED
 ACCORDING TO THE PRODUCT APPROVAL AND
 FRAME DETAIL SPECIFIED BY ENGINEER ON
 SHEET A-6.
 -DRAWINGS IN PRODUCT APPROVAL ARE NOT
 CLEAR AND OR IMCOMPLETE.