| 2001-01-08 00:00:00 | CHECKLIST: |
| | 1-PAY IMPACT FEES. |
| | 2-FOOTING F2 TO BE 16" DEEP MINIMUM. |
| | SECTION 1804.1.3 SBC 1997 AND CITY |
| | AMENDMENTS. |
| | 3-REAR ELEVATION EXCEEDS THE ALLOWED |
| | OPENING PERCENTAGE. TABLE 600 SBC 1997 |
| | 4-CLARIFY/REVISE FLOOR PLANS AND |
| | ELEVATIONS TO MATCH EACH OTHER. |
| | -BE SPECIFIC WITH OPTIONS ON THIS HOUSE |
| | -SEE COMMENTS ON ALL PLANS AND UPDATE/ |
| | REVISE AS REQUIRED. |
| | 5-WINDOW AT BEDROOM #2 DOESN'T MEET THE |
| | EGRESS REQUIREMENTS. SECTION 1005.4.4 |
| | SBC 1997. |
| | -SAME FOR MASTER BEDROOM WINDOW. |
| | 6-A/C FLOOR AREA IN ENERGY CALCULATIONS |
| | DOESN'T MATCH PLANS. |
| | 7-REVISE/CLARIFY SIZE OF SPREAD FOOTINGS |
| | SEE SOIL TEST REPORT FOR RECOMMENDED |
| | MINIMUM DEPTH. |
| | 8-PROVIDE PRODUCT APPROVAL FOR ENTRY |
| | DOOR WITH SIDELITES ASSEMBLY AND |
| | GARAGE DOORS. |
| | 9-PROVIDE COMPLETE INFORMATION FOR |
| | STORM PANELS (OR SEPARATE PERMIT) |
| | 10-FLOOD ZONE "A8" AN ELEVATION |
| | CERTIFICATE WILL BE REQUIRED. |
| | 11-PROVIDE COMPLETE SPECIFICATIONS FOR |
| | CEILING CONSTRUCTION AT FRONT PORCH. |
| | SECTION 104.2 CITY AMENDMENTS. |
| | 12-PROVIDE COMPLETE BUCK DETAILS FOR |
| | EXTERIOR DOORS, WINDOWS AND GARAGE |
| | DOOR. |
| | 13-PROVIDE SAFETY GLASS AS REQUIRED. SEE |
| | PLANS. SEC. 2405.2 SBC 1997. |
| | |
| | NOTE: |
| | PLEASE RETURN REVIEWED SET AFTER |
| | CORRECTIONS ARE DONE IN ORDER TO |
| | EXPEDITE THE REVIEW PROCESS. |