| 2001-01-08 00:00:00 | PLUMBING PROVISO:**NOTE**THE FOLLOWING |
| | ITEMS SHALL BE SUBMITTED FOR REVIEW |
| | PRIOR TO THE ISSUANCE OF THE PLUMBING |
| | PERMIT. |
| | |
| | 1)SUBMIT COPY OF APPROVAL FROM CITY OF |
| | WEST PALM BEACH UTILITIES FOR GREASE |
| | TRAP.COUNTYWIDE AMENDMENTS TO SPC |
| | 101.4.7. |
| | |
| | 2)SHOW LOCATION OF GAS LINE ON CIVIL |
| | DRAWINGS AND CLEARLY SHOW ENTRANCE POINT |
| | INTO BUILDING.PIPING SHALL ONLY BE RUN |
| | UNDER BUILDING SLAB WHEN NO OTHER METHOD |
| | IS AVAILABLE.DETERMINATION SHALL BE MADE |
| | CONTINGENT ON ADDITIONAL INFORMATION. |
| | SGC.SEC.308.3,308.3.2. |
| | |
| | 3)SUBMIT ISOMETRIC DRAWING FOR WATER |
| | PIPING TO WATER HEATERS.COUNTYWIDE AMEND |
| | MENTS TO SPC SEC.104.2.1. |
| | |
| | 4) PH OF EFFLUENT FROM COOLING TOWER |
| | SHALL COMPLY W/SPC SEC.701.5.SUBMIT |
| | DATA FROM CHEMICAL AND/OR COOLING TOWER |
| | MANUF.NOTING PH OF EFFLUENT AT POINT OF |
| | DISCHARGE. |
| | |
| | 5)SUBMIT MANUF.SHEETS FOR ALL SYSTEM |
| | COMPONENTS FOR THE SOVENT SYSTEM.SYSTEM |
| | SHALL COMPLY W/ASSE #1043. |
| | |
| | 6)TWO LAVATORIES ARE REQD.FOR THE MALES |
| | AND FEMALES IN THE RESTAURANT.COMPLY W/ |
| | SPC TABLE 407. |
| | |
| | 7)DRAIN FOR THE DUMPSTER SHALL DISCHARGE |
| | THROUGH THE GREASE INTERCEPTOR.SPC SEC. |
| | 1004.1. |
| | |
| | 8)CIVIL PLANS SHOW DOMESTIC WATER AS 4" |
| | & PLBG.DRAWINGS SHOWS 6". |
| | |
| | 9)LOCATION OF WATER LINES ON PLUMBING |
| | DRAWINGS DO NOT CORRELATE W/PLUMBING |
| | PLANS. |
| | |
| | 10)JOB SPEC.15420-12-SEC.3.9-(C)(E)(F) |
| | (G).PIPING SUPPORTS SHALL COMPLY W/SPC |
| | SEC.310.3. |
| | |
| | 11)JOB SPEC.15430-17-SEC.3.1(W) AND |
| | 15430-22-SEC.3.9(A)-GREASE RECOVERY |
| | UNITS ARE NOT PERMITTED PER CITY ORD. |
| | |
| | 12)JOB SPEC.15430--21-SEC.3.8-GREASE |
| | INTERCEPTOR SHALL COMPLY W/CITY OF WPB |
| | UTILITIES REQS. |
| | |
| | 13)JOB SPEC.15486-6-SEC.3.2(G)-RELIEF |
| | VALVE DRAIN SHALL DISCHARGE TO EXTERIOR |
| | PER COUNTYWIDE AMENDMENTS TO SPC SEC. |
| | 507.6.3. |
| | |
| | NOTE:THE SANITARY FACILITIES ON THE ROOF |
| | ARE IN COMPLIANCE FOR THE OCCUPANT LOAD |
| | OF THE POOL ONLY!APPROVAL MUST BE |
| | OBTAINED FROM THE HEALTH DEPT.PRIOR TO A |
| | APPROVAL FROM THIS DEPT.. ANY OTHER USE |
| | SUCH AS WEDDINGS,PARTIES,ETC.CONSTITUTES |
| | A VIOLATION OF HE STANDARD PLUMBING CODE |
| | SEC.407.1.3.FOR MINIMUM NUMBER OF REQD. |
| | SANITARY FACILITIES. |