| Date |
Text |
| 2001-01-08 00:00:00 | SHT.P-400-DETAIL#13-OUTLET TEE ON GREASE |
| | TRAP SHALL EXTEND TO WITHIN 8"OF BOTTOM |
| | PER WPB UTILITIES REQS.INLETAND OUTLET |
| | ARE REVERSED ON DETAIL. |
| | |
| | SHT.P-100-GAS PIPING SHOWN UNDER SLAB. |
| | PIPING CANNOT BE INSTALLED UNDER SLAB |
| | PER SGC SEC.308.3. |
| | |
| | SHT.P-3.02-SIZE ALL SECTIONS OF THE |
| | SANITARY RISER PER COUNTYWIDE AMENDMENTS |
| | TO SPC SEC.104.2.1. |
| | |
| | HOSE BIBB'S SHALL BE VALVED PER SPC SEC. |
| | 610.3.1. |
| | |
| | CIVIL PLANS AND PLBG.DWGS.SHOW DOMESTIC |
| | WATER SERVICE AS 4"AND SHT.P-500 NOTES |
| | 3".CLARIFY. |
| | |
| | SHT.001-NOTE #3 STATES SANITARY PIPING |
| | SHALL HAVE A 10% SLOPE.COMPLY W/SPC |
| | TABLE 714.1. |
| | |
| | PLANS SHOW A 6" BACKFLOW PREVENTER W/A |
| | 3" METER.CLARIFY. |
| | |
| | PLANS FOR SWIMMING POOL SHALL BE |
| | APPROVED BY HEALTH DEPT.PER COUNTYWIDE |
| | AMENDMENTS TO SPC SEC.101.4.7. |
| | |
| | INDICATE WATER SOURCE FOR IRRIGATION- |
| | IF FROM A WELL OR OTHER ARTIFICIAL |
| | SOURCE A WATER USE PERMIT IS REQD.PER |
| | F.S.373.219. |
| | |
| | LOCATION OF WATER LINES ON CIVIL DWGS. |
| | DON'T CORRELATE W/PLBG.PLANS.CLARIFY. |
| | |
| | FIXTURE DRAINS AND BRANCH DRAINS ON |
| | SOVENT SYSTEM SHALL COMPLY W/ASSE |
| | STANDARD #1043 SEC.3.2(E).(SEE BACK TO |
| | BACK LAVS.) |
| | |
| | NOTE:THE SANITARY FACILITIES ON THE ROOF |
| | ARE IN COMPLIANCE FOR THE OCCUPANT LOAD |
| | OF THE POOL AND SPA ONLY!APPROVAL MUST |
| | BE OBTAINED FROM THE HEALTH DEPT.PRIOR |
| | TO APPROVAL FROM THIS DEPT.ANY OTHER |
| | USE SUCH AS WEDDINGS,PARTIES,ETC, |
| | CONSTITUTES A VIOLATION OF THE STD. |
| | PLUMBING CODE SEC.407.1.3 FOR NUMBER |
| | OF MINIMUM REQUIRED SANITARY FACILITIES. |
| | |
| | **************ADDENDUM****************** |
| | SECONDARY DRAINAGE SYSTEM FOR ROOF SHALL |
| | COMPLY W/SPC SEC.1109.2,1109.3,AND |
| | APPENDIX"A".(THE OVERFLOW SYSTEM IS |
| | INADEQUATE AS DESIGNED.THE 4" OVERFLOW |
| | DRAINS WILL NOT CARRY THE ADJUSTED SQ. |
| | FOOTAGE.) |
| | |
| | CLEARLY INDICATE SQ.FOOT AREA OF THE |
| | ROOF AND THE SLOPE OF THE STORM DRAINAGE |
| | PIPING ABOVE AND BELOW GROUND.COMPLY W/ |
| | TABLES 1108.1 &1108.2 OF SPC. |