| Date |
Text |
| 2001-01-08 00:00:00 | P-400, I CAN NOT FIND A LOCATION AS TO |
| | WHERE THE STORM DRAIN BUBBLER DETAIL IS |
| | GOING TO BE BUILT.PLEASE CALL OUT THE |
| | EXACT LOCATION, SINCE THERE IS NO |
| | PRIVATE PROPERTY THIS CAN BE PLACED ON |
| | UNLESS IT IS IN THE DUMPSTER ENCLOSURE. |
| | |
| | THE FOLLOWING COMMENTS MAY NOT BE VALID |
| | SINCE IT IS MY UNDERSTANDING THAT THE |
| | ALLEYWAY PAVER AND LANDSCAPE PLAN HAS |
| | BEEN REDRAWN, BUT NOT SUBMITTED WITH |
| | THIS PLAN SET FOR REVIEW: |
| | |
| | SHEET SERIES L1.0, PAVER DESIGN DOES NOT |
| | MATCH EXISTING PAVERS WITH CIRCULAR |
| | DESIGN AT THE POINT OF CONNECTION |
| | BETWEEN DATURA AND THE ALLEY. |
| | |
| | THE EXISTING PLAN DOES NOT SHOW THE |
| | EXISTING PALM TREES.PERMISSION FROM |
| | THE CITY WILL BE REQUIRED TO PERMANENTLY |
| | REMOVE THE TREES.THE TREES NEED TO BE |
| | REMOVED DURING CONSTRUCTION BY THE |
| | CONTRACTOR TO SAFE GUARD THEM.OR |
| | REPLACED BY THE CONTRACTOR PRIOR TO |
| | RECEIVING YOUR CO. |
| | |
| | THE EXISTING IRRIGATION SYSTEM IS NOT |
| | SHOWN TO BE CUT BACK TO THE END OF THE |
| | LAST SERVICE TEE. WHICH IS REQUIRED IF |
| | THE TREES ARE NOT TO GO BACK IN AS SHOWN |
| | ON YOUR PLAN. |
| | |
| | THE ELECTRIC LINE TO THE TREE "UP |
| | LIGHTS" AND TO THE STATUE AT DATURA AND |
| | THE ALLEY NEEDS TO BE RECONFIGURED.IF |
| | THE TREES WILL NOT BE PUT BACK THOSE |
| | LINES NEED TO BE CUT OUT, BUT THE WIRING |
| | REMAIN. |
| | |
| | THE STATUE WILL NEED TO BE PROTECTED. |
| | YOU WILL NEED TO GET PERMISSION TO |
| | REMOVE IT TILL THE BUILDING IS NEAR |
| | COMPLETION. |
| | |
| | THE PLANTERS ON NARCISSUS WILL NOT HAVE |
| | TREE GRATES AND BURIED "UP LIGHTS".USE |
| | THE 1' HIGH GREEN FENCE AND PLANTS AS |
| | USED ON THE PLANTERS ON NARCISSUS NORTH |
| | AND SOUTH OF CLEMATIS.THE LIGHTS MUST |
| | BE ABOVE GROUND INSIDE THE PLANTERS. |
| | |
| | ADDITIONALLY DELETE THE GALVANIZED STEEL |
| | CHANNEL EDGE FOR THE TREE GRATES TO SIT |
| | IN. |