Plan Review Notes
Plan Review Notes For Permit 99121094
Permit Number 99121094
Review Stop R
Sequence Number 1
Notes
Date Text
2001-01-08 00:00:00CHECKLIST:
 1-PAY IMPACT FEES.
 2-UPDATE/REVISE ALL DRAWINGS. SEE
 COMMENTS ON PLANS.
 3-FLOOD ZONE A8. WILL NEED TO PROVIDE
 AN ELEVATION CERTIFICATE.
 4-ENGINEER TO SIGN, SEAL AND DATE THE
 SOIL TESTS REPORT.
 5-REVISE SIZE OF BEDROOM #2 WINDOW TO
 MEET THE EGRESS REQUIREMENTS. SEC
 1005.4.4 SBC 1997.
 6-STORM PANELS:
 -PRODUCT APPROVAL DOESN'T MATCH DWGS.
 -REVISE/UPDATE INSTALLATION SCHEDULE
 AND KEY PLAN TO MATCH FLOOR PLANS.
 COMPLETELY FILL THE INSTALLATION
 SCHEDULE AS PER CITY SAMPLE. ATTACHED.
 -NOTE: SPECIFY ANCHOR SPACING ACCORDING
 TO THE BUILDING CONSTRUCTION. THIS IS
 MASONRY CONSTRUCTION, NOT CONCRETE.
 HIGHLIGHT ALL MOUNTING CONDITIONS AND
 ANCHORS TO BE USED.
 7-PROVIDE COMPLETE BUCK DETAILS FOR
 EXTERIOR DOORS, WINDOWS AND GARAGE
 DOOR.
 8-PROVIDE PRODUCT APPROVAL FOR ENTRY
 DOOR WITH SIDELITES ASSEMBLY AND
 GARAGE DOOR.