| Plan Review Notes For Permit 99110858 |
| Permit Number |
99110858 |
|
| Review Stop |
P |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2001-01-08 00:00:00 | SHT.PD-P3.01-MAX.20,700 SQ.FT.PERMITTED | | | ON 10" RWL AT 1/8" PER FT.(SEE COLS.B-2 | | | C-2,C-8.)COMPLY W/SPC 1108.2. | | | | | | SHT.PD-P3.01-PLANS SHOW 15"RWL DRAINING | | | INTO 10" LINE.SPC SEC.307.5,709.1.SEE | | | COL.C-5.2. | | | | | | SIZE THE UNDERGROUND HORIZONTAL SECTIONS | | | FOR ALL THE STORM RISERS.COMPLY W/SPC | | | SEC.1108.2 AND TABLE 1108.2. | | | | | | CLEARLY SHOW PROVISIONS FOR OVERFLOW | | | DRAINAGE PER SPC 1109.1-1109.3.SUBMIT | | | DETAILS OF OVERFLOW OPENINGS. | | | | | | SUBMIT CALCULATIONS FOR INCLUSION OF | | | 1/2 THE AREA OF ANY VERTICAL WALL WHICH | | | DIVERTS RAIN WATER TO THE ROOF.SPC SEC. | | | 1108.3. |
|