Plan Review Notes
Plan Review Notes For Permit 99110462
Permit Number 99110462
Review Stop ENG
Sequence Number 1
Notes
Date Text
2001-01-08 00:00:00PASSED WITH PREVISOS:
 1. REVIEW CITY LANDSCAPE ARCHITECTS COMM
 COMMENTS ABOUT REQUIREMENTS OF REMOVINGM
 FICUS TREES.RETE APRON NEEDS TO HAVE A C
 2. THE CONCRETE APRON CAN NOT BE THE
 SAME ELEVATION OF THE BERM.THEN THE
 WATER WILL SEEK IT'S ON LEVEL AND EXIT
 ANY WHERE ON THE BERM AND OR APRON.
 EITHER DROP THE THE APRON, WHICH MAY
 MEAN RECALCULATING THE AREA OF RETENTION
 OR RAISE THE BERM AT KLEAST THREE
 INCHES.
 3.THE CONCRETE APRON NEEDS TO HAVE A
 CURB ALONG THE EAST AND WEST SIDES TO
 STOP THE WATER FROM FLOWING OVER THE
 EDGE AND WASHING OUT THE BERM ON EITHER
 SIDE.