| Plan Review Notes For Permit 99101414 |
| Permit Number |
99101414 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2001-01-08 00:00:00 | SIZE OF HANDICAP STALLS DO NOT COMPLY W/ | | | FACBC.COMPLY W/FACBC SEC.4.17.3.(SEE | | | EXCEPTION:NEW CONSTRUCTION) | | | | | | SUBMIT ELEVATION DETAILS FOR ALL HANDI- | | | CAP FIXTURES.COMPLY W/FACBC 1997 EDITION | | | | | | CLEARLY SHOW TERMINATION POINT OF SUMP | | | DRAIN IN ELEVATOR.DRAIN SHALL CONNECT TO | | | SANITARY SYSTEM THROUGH AN INDIRECT | | | WASTE.IF ELEVATOR IS HYDRAULIC,AN OIL | | | INTERCEPTOR WILL BE REQD.SPC SEC.1004.5. | | | | | | FLOOR DRAINS NOT PERMITTED ON STORM | | | DRAIN PER SPC SEC.1106.4. | | | | | | SHT.P4.1-RELIEF LINE AND PAN DRAIN SHALL | | | DISCHARGE TO EXTERIOR PER COUNTYWIDE | | | AMENDMENTS TO SPC SEC.507.6. |
|