Plan Review Notes For Permit 99101414
Permit Number 99101414
Review Stop P
Sequence Number 1
Notes
Date Text
2001-01-08 00:00:00SIZE OF HANDICAP STALLS DO NOT COMPLY W/
 FACBC.COMPLY W/FACBC SEC.4.17.3.(SEE
 EXCEPTION:NEW CONSTRUCTION)
  
 SUBMIT ELEVATION DETAILS FOR ALL HANDI-
 CAP FIXTURES.COMPLY W/FACBC 1997 EDITION
  
 CLEARLY SHOW TERMINATION POINT OF SUMP
 DRAIN IN ELEVATOR.DRAIN SHALL CONNECT TO
 SANITARY SYSTEM THROUGH AN INDIRECT
 WASTE.IF ELEVATOR IS HYDRAULIC,AN OIL
 INTERCEPTOR WILL BE REQD.SPC SEC.1004.5.
  
 FLOOR DRAINS NOT PERMITTED ON STORM
 DRAIN PER SPC SEC.1106.4.
  
 SHT.P4.1-RELIEF LINE AND PAN DRAIN SHALL
 DISCHARGE TO EXTERIOR PER COUNTYWIDE
 AMENDMENTS TO SPC SEC.507.6.