| Plan Review Notes For Permit 99100445 |
| Permit Number |
99100445 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2001-01-08 00:00:00 | DRINKING FOUNTAIN SHALL BE HANDICAP | | | ACCESSIBLE AND COMPLY W/ FACBC SEC. | | | 4.1.3(10)(A) AND FIGURE 27. | | | | | | FLOOR DRAINS ARE REQD.IN THE TOILET | | | ROOMS PER SPC SEC.409.4.1.1. | | | | | | CLEARLY SHOW ON PLANS THAT WALLS AND | | | FLOORS ARE NON-ABSORBENT TO A HEIGHT OF | | | 4 FEET PER SBC SEC.1204.2.(INDICATE ON | | | FINISH SCHEDULE.) | | | | | | EACH PUBLIC AND COMMON USE TOILET ROOM | | | SHALL COMPLY W/FACBC SEC.4.1.3.(11), | | | 4.22. | | | | | | PUBLIC AND COMMON USE BATHING ROOMS | | | SHALL COMPLY W/FACBC SEC.4.23 PER FACBC | | | SEC.4.1.3.(11). | | | | | | WATER FILTER SYSTEM SHALL BE NSF | | | APPROVED PER SPC SEC.615.1. | | | | | | WATER SUPPLY CONTROL SHALL COMPLY W/SPC | | | SEC.610.4.2.(CONTROL VALVES REQD.ON | | | BRANCH LINES.) | | | | | | SIZING OF VENTS FOR SINKS IN EXAM ROOMS | | | SHALL COMPLY W/TABLE 920.2.(2" EXCEEDS | | | LIMITS.) | | | | | | NOTE OCCUPANT LOAD ON PLANS TO ENSURE | | | COMPLIANCE W/SPC TABLE 407.COMPLY W/SEC. | | | 407.1.3. |
|