| 2001-01-08 00:00:00 | STORM WATER REQUIREMENTS: TO OBTAIN A |
| | CONSTRUCTION PERMIT. THE FOLLOWING MUST |
| | BE SUBMITTED SIGNED AND SEALED BY A |
| | FLORIDA PROFESSIONAL ENGINEER (PE): |
| | 1) CONSTRUCTION PLANS, |
| | 2) DETAILS AND SPECIFICATIONS, |
| | 3) HYDRAULIC COMPUTATIONS AND |
| | SUPPORTING DOCUMENTATION, |
| | 4) IMPERVIOUS AREA COMPUTATIONS, |
| | POLLUTION PREVENTION PLAN. |
| | THE POLLUTION PREVENTION PLAN SHALL BE |
| | KEPT ON SITE AT ALL TIMES DURING |
| | CONSTRUCTION. THE PLAN SHALL BE |
| | INSTALLED IN THE FIELD PRIOR TO ANY |
| | EARTHWORK. THE ENGINEER OF RECORD |
| | SHALL CERTIFY TO THE CITY, ON A MONTHLY |
| | BASIS, THAT THE PLAN IS WORKING PROPERLY |
| | AND AS DESIGNED. THE ENGINEER OF RECORD |
| | IS RESPONSIBLE TO CERTIFY |
| | IMPLEMENTATION OF THE PROVISIONS OF |
| | CITY ORDINANCE NO. 3132-98 OF THE CITY |
| | CODE AT SUCH TIME THE PERMITTEE APPLIES |
| | FOR A CERTIFICATE OF OCCUPANCY FROM THE |
| | CITY BUILDING OFFICIAL. |
| | EVERY SIX MONTHS AFTER CONSTRUCTION A |
| | PE SHALL CERTIFY THAT THE PERMANENT |
| | POLLUTION PREVENTION STRUCTURES, DRY- |
| | WET WATER DETENTION FACILITIES, AND |
| | EXFILTRATION SYSTEMS ARE WORKING AS |
| | DESIGNED AND ARE IN GOOD OPERATING |
| | CONDITION. |
| | ALL CERTIFICATIONS MUST BE SUBMITTED |
| | TO: STORM WATER UTILITY ENGINEER, CITY |
| | OF WEST PALM BEACH, PUBLIC UTILITIES |
| | DEPARTMENT, P.O. BOX 3366, WEST PALM |
| | BEACH, FLORIDA 33402. THE CERTIFICATION |
| | MUST INCLUDE THE BUILDING PERMIT |
| | NUMBER, THE ADDRESS OF THE PROPERTY AND |
| | THE NAME OF THE ESTABLISHMENT/PROJECT |
| | CONSTRUCTED. |
| | SANITATION: |
| | NO DUMPSTER ENCLOSURE SHOWN. STATE IF IT |
| | IS TO BE CITY PICK UP OR PRIVATE.IF |
| | CITY PICKUP THEN THE FOLLOWING |
| | REQUIREMENTS MUST BE MET; DUMPSTER MUST |
| | HAVE A MINIMUM OF 12' OPENING BETWEEN |
| | THE GATE POSTS.INTERIOR DIMENSIONS OF |
| | THE ENCLOSURE MUST BE A MINIMUM OF 12' |
| | WIDE AND 12' DEEP.A CONCRETE PARKING |
| | STOP BAR MUST BE CENTERED (FROM GATES) |
| | AND INSTALLED 18" FROM THE BACK WALLED. |
| | STEEL BARS WILL BE DRILLED OR THRU THE |
| | STOP BAR AND INTO THE INTERIOR FLOOR OF |
| | THE ENCLOSURE TO STOP THE BAR FROM MOVIN |
| | WHEN THE DUMPSTER IS SET INSIDE. THE |
| | OPENING OF THE DUMPSTER ENCLOSURE MUST |
| | BE PLACED SO THAT A 40' LONG TRUCK WITH |
| | THE FORKS EXTENDED CAN APPROACH THE |
| | OPENING AND PICK UP THE DUMPSTER WITHOUT |
| | TURNING A SHARP TURN. NOTHING MAY BE |
| | PLACED OVERHEAD IN THE AREA WHERE THE |
| | DUMPSTER ENCLOSURE IS SO THAT WHEN THE |
| | DUMPSTER IS PICKED UP AND DUMPED THE |
| | DUMPSTER NOR THE TRUCK OR TRUCK FORKS |
| | WILL BE IMPEDED. |
| | WATER AND SANITARY APPROVED WITH DEP PER |
| | THE CORE ROAD PALNS. |