Plan Review Notes
Plan Review Notes For Permit 99091007
Permit Number 99091007
Review Stop R
Sequence Number 1
Notes
Date Text
2001-01-08 00:00:00 
 APPROVED WITH PROVISO:
 1-PLEASE REVISE ALL ORIGINALS SHOWING
 ALL CORRECTIONS/CLARIFICATIONS.
 2-PROVIDE SAFETY GLASS IN LIBRARY WINDOW
 SEC. 2405.2 SBC 1997.
 3-ENTRY DOOR TO HAVE 32" MINIMUM CLEAR
 OPENING. TABLE 1004 SBC 1997.
 4-ENGINEERED TRUSS DRAWINGS:
 -UPDATE ALL DETAILS.
 -UPDATE DESIGN CRITERIA
 -ENGINEER OF RECORD TO REVIEW ALL
 TRUSS DRAWINGS PRIOR TO SUBMITTAL.
 5-REVISE DESIGN CERTIFICATION FOR WIND
 LOAD COMPLIANCE FORM. MEAN ROOF HEIGHT
 IS INCORRECT (21'-0" PLUS O MINUS).
 6-SPECIFY SIZE OF CEILING FANS. TABLE
 6-6 FLORIDA ENERGY CODE 1997 EDITION.
 CREDIT FOR CEILING FANS WAS TAKEN ON
 THE ENERGY CALCULATIONS.
 7-PROVIDE FULL SET OF PRODUCT APPROVALS
 (MASTER PERMIT IS ON HOLD TILL ALL
 PLANS AND PRODUCT APPROVALS ARE
 COMPLETELY PREPARED).
 8-STORM PANELS:
 PROVIDE A COMPLETE INSTALLATION
 SCHEDULE,AS PER CITY SAMPLE, ATTACHED,
 AND KEY PLAN. HIGHLIGHT SPECIFIC
 MOUNTING CONDITIONS AND ANCHOR SCHED.
 9-PROVIDE ATTIC ACCESS AT MAIN ROOF.
 SEC. 2309.6 SBC 1997.
 10-PROVIDE COMPLETE SPECIFICATIONS FOR
 CEILINGS AT FRONT AND BACK PORCH.
 SEC. 104.2.2 CITY AMENDMENTS.
 11-PROVIDE COMPLETE DETAILS AND SPECS
 FOR MOUNTING OF AHU'S.
 SEC. 104.2.2 CITY AMENDMENTS.