2001-01-08 00:00:00***************DENIED******************
  
 1)NOTE:AS PER ART:220-3-D-1 ADDITIONS
 OVER 500 SQ.FT. NEED TO HAVE LOAD CALCS.
 2)NOTE;AS PER 250-24-C-1,2,3 SEPARTE
 DISC.MEANS IS REQ`D IF YOU MEET THAT
 CODE ART.IF BATH IS INSTALLED THEN BATH
 REQ`D CIRCUT AND RECEPT.AS PER ART;
 210-52D
  
  
 PLEASE PROVIDE EXISTING RISER DIAGRAM,
 SHOWING SIZE OF SERVICE,WIRE,AND LOADS.
 IF DETACHED GARAGE MEETS THE REQ`MENTS
 OF 250-24C THEN SHOW THE MEANS OF DISC.
 (PANEL) FEED,PIPE SIZE, WIRE,GROUNDING
 ELECTRODE SYSTEM, ETC.