| Date |
Text |
| 2001-01-08 00:00:00 | MOP SINK REQUIRES INDIVIDUAL VENT PER |
| | COUNTYWIDE AMENDMENTS TO STANDARDPLBG. |
| | CODE SEC.911.1 |
| | |
| | PLANS SHALL BE REVIEWED AND APPROVED BY |
| | DEPT.OF BUSINESS REGULATION PRIOR TO |
| | APPROVAL BY THE CITY OF W.P.B.BLDG.DEPT. |
| | PER SPC SEC.101.4.7. |
| | |
| | FLOOR SINKS BY BUFFET AREA NOT SHOWN ON |
| | SANITARY RISER AND ARE NOT PROPERLY |
| | VENTED.SPC SEC.908.1 & TABLE 908.1. |
| | |
| | WATER CLOSETS AND FIXTURE BRANCHES NOT |
| | PERMITTED ON WET VENTS PER COUNTYWIDE |
| | AMENDMENTS TO PLBG.CODE SEC.911.1. |
| | |
| | NO MORE THAN 2 WATER CLOSETS ARE |
| | PERMITTED ON 3" DRAIN PER TABLES 714.1 & |
| | 714.2 FOOTNOTES #3 AND #2. |
| | |
| | SIZE ALL SECS.OF THE DRAIN, WASTE AND |
| | VENT SYSTEM.SPC 104.2.1. |
| | |
| | SIZE ALL SECTIONS OF THE WATER RISER.SPC |
| | SEC.104.2.1. |
| | |
| | SIZE ALL SECTIONS OF THE GAS RISER PER |
| | STD.GAS CODE SEC.302 AND NFPA 54. |
| | |
| | ALL GAS EQIUPMENT SHALL BE APPROVED PER |
| | STD.GAS CODE 402 AND NFPA 54.SUBMIT |
| | MANUF.SHEETS. |
| | |
| | WATER SUPPLY CONTROL SHALL COMPLY W/SPC |
| | SEC.610.4.1, 610.4.2. |
| | |
| | OVER 2 FIXTURES SUPPLIED BY 1/2" C.W. |
| | LINE.PER COUNTYWIDE AMENDMENTS SEC.607.7 |
| | |
| | NO "M" COPPER PERMITTED U/G.PER COUNTY- |
| | WIDE AMENDMENTS TO PLBG.CODE SEC.611.3. |
| | |
| | COMPLY W/PREVIOUS COMMENTS DATED 10/7/99 |
| | |
| | REVISIONS SHALL BE ATTACHED TO MASTER |
| | SET OF PLANS. |