| Plan Review Notes For Permit 99090086 |
| Permit Number |
99090086 |
|
| Review Stop |
R |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2001-01-08 00:00:00 | APPROVED WITH PROVISO: | | | 1-PLEASE REVISE ALL ORIGINAL DRAWINGS | | | SHOWING ALL CLARIFICATIONS/CORRECTIONS | | | AS REQUESTED ON PLANS. | | | 2-PROVIDE 32" MINIMUM CLEAR OPENING AT | | | ENTRY DOOR. TABLE 1004 SBC 1997. | | | 3*PROVIDE PRODUCT APPROVAL FOR FIXED | | | WINDOW AT LIVING AREA. CLARIFY IF | | | WINDOW IS TO HAVE MULLIONS OR MUNTINS. | | | *SAME CLARIFICATION IS REQUIRED FOR | | | FIXED WINDOW AT FAMILY AREA. | | | 4-PROVIDE DESIGN PRESSURES FOR ALL | | | EXTERIOR OPENINGS. SEC 1606 SBC 1997. | | | 5-SPECIFY SIZES OF CEILING FANS AS PER | | | TABLE 6-6 FLORIDA ENERGY CODE, 1997. | | | SEE ENERGY CALCULATIONS FOR CREDIT | | | TAKEN FOR CEILING FANS. | | | 6-PROVIDE ATTIC ACCESS AT MAIN ROOF. | | | SEC. 2309.6 SBC 1997. | | | 7-PROVIDE TWO COPIES OF ENGINEERED | | | TRUSSES, SIGNED AND SEALED AND REVIEWED | | | BY DESIGNER OF RECORD. | | | 8-PROVIDE KNEEWALL DETAIL AT LOCATION | | | MARKED ON DRAWING #7. SEE PLANS. | | | 9-PROVIDE A COMPLETE INSTALLATION | | | SCHEDULE AS PER CITY SAMPLE AND KEY | | | PLAN FOR STORM PANELS. |
|