| Plan Review Notes For Permit 99090078 |
| Permit Number |
99090078 |
|
| Review Stop |
R |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2001-01-08 00:00:00 | APPROVED WITH PROVISO: | | | 1-PLEASE REVISE ALL ORIGINALS SHOWING | | | ALL CLARIFICATIONS/CORRECTIONS MARKED | | | ON SUBMITTED DRAWINGS. | | | 2-PROVIDE SAFETY GLASS IN LIBRARY WINDOW | | | SEC. 2405.2 SBC 1997 | | | 3-PROVIDE SPECIFICATIONS OF HOW TO | | | COMPLY WITH SEC. 402.7.2 SGC 1997 FOR | | | INSTALLATION OF GAS APPLIANCES IN THE | | | GARAGE. | | | 4-ENTRY DOOR TO HAVE 32" MINIMUM CLEAR | | | OPENING. TABLE 1004 SBC 1997. | | | 5-PROVIDE TWO COPIES OF ENGINEERED ROOF | | | TRUSSES SIGNED AND SEALED AND REVIEWED | | | BY DESIGNER OF RECORD. | | | 6-REVISE DESIGN CERITIFICATION FOR WIND | | | LOAD COMPLIANCE FORM. MEAN ROOF HEIGHT | | | IS 21"-0" MORE OR LESS. | | | 7-SPECIFY SIZE OF CEILING FANS. TABLE | | | 6-6 FLORIDA ENERGY CODE 1997 EDITION. | | | CREDIT FOR CEILING FANS WAS TAKEN ON | | | ENERGY CALCULATIONS. | | | 8-PROVIDE PRODUCT APPROVAL FOR WINDOW AT | | | DINING AREA. CLARIFY IF WINDOW AT | | | LIVING AREA HAS TRUE VERTICAL MULLIONS | | | OR FALSE MULLIONS IN ORDER TO VERIFY | | | SIZE OF FIXED WINDOW. | | | 9-STORM PANELS: PROVIDE A COMPLETE | | | INSTALLATION SCHEDULE (AS PER CITY | | | SAMPLE) AND KEY PLAN. | | | 10-PROVIDE ATTIC ACCESS TO MAIN ROOF. | | | SEC 2309.6 SBC 1997. |
|