| Date |
Text |
| 2001-01-08 00:00:00 | CHECKLIST: |
| | 1-PAY IMPACT FEES TO THE COUNTY. |
| | 2-ALL DRAWINGS TO BE SIGNED, SEALED AND |
| | DATED BY ARCHITECT. SEC 104.2.1 CITY |
| | AMENDMENTS TO SBC 1997. |
| | 3-SPECIFY IF THE OPTIONAL REAR PORCH IS |
| | GOING TO BE BUILT IN ORDER TO PROPERLY |
| | ASSESS THE RADON FEES. |
| | IF SO, PROVIDE COMPLETE CONSTRUCTION |
| | DETAILS. |
| | 4-PROVIDE THE DESIGN PRESSURES AT ALL |
| | EXTERIOR OPENINGS. SEC 1606 SBC 1997. |
| | 5-PROVIDE PRODUCT APPROVALS FOR: |
| | BUTT GLAZING, FIREPLACE, WINDOW AND |
| | DOOR MULLIONS, ENTRY DOOR ASSEMBLY WITH |
| | TRANSOM ABOVE, FIXED WINDOW AT FAMILY |
| | AND LIVING ROOM, ROOF TILE (UNDER A |
| | SEPARATE PERMIT), SLIDING GLASS DOORS. |
| | 6-PROVIDE SPECIFICATIONS OF HOW TO |
| | COMPLY WITH SECTION 402.7 SGC 1997 FOR |
| | INSTALLATION OF GAS APPLIANCES IN GARAG |
| | 7-PROVIDE COMPLETE INSTALLATION DETAILS |
| | FOR AHU'S IN ATTIC. |
| | 8-PROVIDE COMPLETE INSTALLATION DETAILS |
| | FOR CONSTRUCTION OF MULLIONS BETWEEN |
| | WINDOWS AT FRONT OF THE HOUSE(SEE ELEV) |
| | 9-PROVIDE ATTIC ACCESS. SEC 2309.6 SBC |
| | 10-PROVIDE COMPLETE DETAIL/SECTION FOR |
| | CHIMNEY CONSTRUCTION. |
| | 11-PROVIDE COMPLETE COLUMN SCHEDULE. |
| | 12-SPECIFY CEILING CONSTRUCTION AT FRONT |
| | AND REAR PORCHES. SEC 2504.2 SBC 1997 |
| | AS PER ASTM C926 AND ASTM C1063. |
| | 13-DESIGN LOADS ON SHEET S2 AND DESIGN |
| | CERTIFICATION FOR WIND LOAD COMPLIANCE |
| | FORM ARE DIFFERENT. REVISE AS REQUIRED. |
| | 14-SPECIFY TEH CEILING FANS AS PER |
| | CREDIT TAKEN IN ENERGY CALCULATIONS. |
| | 15-FOOTING F2 IS ENCROACHING INTO THE |
| | NEIGHBOR'S PROPERTY AT ZERO LOT LINE. |
| | REVISE AS REQUIRED. |
| | 16-STORM PANELS: |
| | *REVISE INSTALLATION SCHEDULE. EG: |
| | OPENINGS #1,2,6,7. |
| | *REVISE ANCHOR SCHEDULE. ANCHOR AND |
| | SPACING SPECIFIED IS GOOD ONLY FOR |
| | 3000 PSI CONCRETE. CONSTRUCTION OF THIS |
| | HOUSE IS HOLLOW CONCRETE BLOCK. |
| | *PROVIDE DETAIL SHOWING INSTALLATION |
| | OF STORM PANEL AT FRONT WINDOWS WHERE |
| | THERE IS AN ELABORATED TRIM AROUND THEM |
| | 17-PROVIDE COMPLETE SPECIFICATIONS AND |
| | DETAILS FOR INSTALLATION OF BUTT |
| | GLAZING. SEC 104.2.1 CITY AMENDMENTS. |
| | 18-SEE PLANS FOR ADDITIONAL COMMENTS. |
| | 19-PROVIDE ENGINEERED TRUSS DRAWINGS. |
| | REVIEWED BY DESIGNER OF RECORD PRIOR TO |
| | SUBMITTAL TO THIS OFFICE. |