| Plan Review Notes For Permit 99080933 |
| Permit Number |
99080933 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2001-01-08 00:00:00 | INDICATE TYPE OF PIPING MATERIAL TO BE | | | INSTALLED FOR GAS SYSTEM.COMPLY W/STD. | | | GAS CODE SEC.306. | | | | | | SUBMIT MANUF.SHEETS FOR GAS EQUIPMENT. | | | COMPLY W/STD.GAS CODE SEC.402.1. | | | | | | SUPPLY CALCULATIONS FOR COMBUSTION AIR | | | FOR WATER HEATER AND DRYERS.COMPLY W/ | | | STD.GAS CODE SEC.402.4. | | | | | | SIZE ALL SECTIONS OF THE WATER RISER.NO | | | MORE THAN 2 FIXTURES SHALL BE CONNECTED | | | TO A 1/2" C.W. LINE AND 4 FIXTURES TO A | | | H.W.LINE PER COUNTYWIDE AMENDMENTS SEC. | | | 607.7. | | | | | | A VENT IS REQD.ON THE FLOOR DRAIN FOR | | | THE WASHING MACHINES PER SPC SEC.901.2. | | | | | | INDICATE SLOPE OF SANITARY SYSTEM AND | | | NOTE FIXTURE LOAD PER SPC TABLE 713.1 | | | FOOTNOTE #3 AND NOTE SIZE OF STANDPIPE. | | | SPC 1001.9.1. | | | | | | FLOOR DRAINS ARE REQD.IN THE TOILET | | | ROOMS PER SPC 409.4.1.1. | | | | | | WALLS IN TOILET ROOMS SHALL BE NON- | | | ABSORBENT MATERIAL TO 4' PER SBC SEC. | | | 1204.2 | | | | | | DRINKING FOUNTAIN SHALL COMPLY W/FACBC | | | SEC.4.1.3(10)(A). | | | | | | ` |
|