2001-01-08 00:00:00PASSED WITH PROVISO:
 SANITATION:
 NO DUMPSTER LOCATION SHOWN.
 IF GARBAGE IS TO BE PICKED UP BY CITY OR
 IF IT IS PRIVATE PICKUP, IF TO BE PICKED
 UP BY THE CITY THEN THE FOLLOWING
 REQUIREMENTS MUST BE MET:
  
 1.DUMPSTER MUST HAVE A MINIMUM OF 12'-6"
 OPENING BETWEEN THE GATE POSTS.
  
 2.INTERIOR DIMENSIONS OF THE ENCLOSURE
 MUST BE A MINIMUM OF 12'-6" WIDE AND 12'
 DEEP.A CONCRETE PARKING STOP BARS 10'
 LONG MUST BE CENTERED (FROM GATES) AND
 INSTALLED 18" FROM THE BACK WALL.STEEL
 BARS WILL BE DRILLED THRU THE STOP BAR
 AND INTO THE INTERIOR FLOOR OF THE
 ENCLOSURE TO STOP THE STOP BAR FROM
 MOVING WHEN THE DUMPSTER IS SET INSIDE.
  
 3.THE OPENING OF THE DUMPSTER ENCLOSURE
 MUST BE ANGLED SO THAT A 40' LONG TRUCK
 WITH THE FORKS EXTENDED CAN APPROACH THE
 OPENING AND PICK UP THE DUMPSTER WITHOUT
 MAKING A SHARP TURN.
  
 4.THE TRUCK NEEDS TO HAVE NO LESS THAN A
 16' HIGH VERTICAL CLEARANCE AREA FOR THE
 TRUCK TO PICK UP THE DUMPSTER. THE CLEAR
 AREA MUST OVER THE DUMPSTER AND WHERE
 THE TRUCK WILL BE STOPPED TO UNLOAD THE
 DUMPSTER.
  
 5.THE TRUCK NEEDS TO HAVE NO LESS THAN
 14' HIGH VERTICAL CLEARANCE AND 12'
 HORIZONTAL CLEARANCES FOR THE TRUCK TO
 DRIVE THROUGH.
  
 6.IT IS STRONGLY SUGGESTED THAT YOU ADD
 A RECYCLING CENTER TO YOUR DUMPSTER
 ENCLOSURE.