Plan Review Notes
Plan Review Notes For Permit 99071788
Permit Number 99071788
Review Stop R
Sequence Number 1
Notes
Date Text
2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-REVISE ALL ORIGINAL DRAWINGS WITH ALL
 THE CORRECTIONS.SEE PLANS FOR COMMENTS
 2-FOOTING F2 TO BE 16"MIN. DEEP AS PER
 SEC 1804.1.3 SBC 1997 AND SEC 1804.1.9
 OF CITY AMENDMENTS.
 3-SPECIFY HOW TO COMPLY WITH SECTION
 402.7 SGC 1997, REGARDING PROTECTION
 OF GAS APPLIANCES IN GARAGE.
 4-ENTRY DOOR TO HAVE 32" MINIMUM CLEAR
 OPENING.TABLE 1004 SBC 1997.
 5-PROVIDE SAFETY GLASS WHERE REQUIRED.
 SEC. 2405.2 SBC 1997.
 6-PROVIDE PRODUCT APPROVAL FOR ROUND
 WINDOWS, OVAL WINDOW, BUTT GLAZING,
 6'X7' GARAGE DOOR.
 7-STORM PANELS:
 PROVIDE COMPLETE INSTALLATION SCHEDULE
 AND KEY PLAN.
 HIGHLIGHT SPECIFIC MOUNTING DETAILS
 AND ANCHORS TO BE USED.
 8-ARCHITECT/ENGINEER TO PROVIDE THE
 DESIGN PRESSURES AT ALL EXTERIOR
 OPENINGS.
 9-SPECIFY CONSTRUCTION AT FRONT AND REAR
 PORCH CEILINGS AS PER SEC 2504.2 SBC
 1997.
 10-PROVIDE TWO COPIES OF ENGINEERED ROOF
 TRUSSES SIGNED AND SEALED.
 NOTE:TRUSS LAYOUT NEEDS TO BE SIGNED
 AND SEALED BY TRUSS ENGINEER TOO.


Account Summary | Usage Policy | Privacy Policy