| Plan Review Notes For Permit 99071788 |
| Permit Number |
99071788 |
|
| Review Stop |
R |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2001-01-08 00:00:00 | APPROVED WITH PROVISO: | | | 1-REVISE ALL ORIGINAL DRAWINGS WITH ALL | | | THE CORRECTIONS.SEE PLANS FOR COMMENTS | | | 2-FOOTING F2 TO BE 16"MIN. DEEP AS PER | | | SEC 1804.1.3 SBC 1997 AND SEC 1804.1.9 | | | OF CITY AMENDMENTS. | | | 3-SPECIFY HOW TO COMPLY WITH SECTION | | | 402.7 SGC 1997, REGARDING PROTECTION | | | OF GAS APPLIANCES IN GARAGE. | | | 4-ENTRY DOOR TO HAVE 32" MINIMUM CLEAR | | | OPENING.TABLE 1004 SBC 1997. | | | 5-PROVIDE SAFETY GLASS WHERE REQUIRED. | | | SEC. 2405.2 SBC 1997. | | | 6-PROVIDE PRODUCT APPROVAL FOR ROUND | | | WINDOWS, OVAL WINDOW, BUTT GLAZING, | | | 6'X7' GARAGE DOOR. | | | 7-STORM PANELS: | | | PROVIDE COMPLETE INSTALLATION SCHEDULE | | | AND KEY PLAN. | | | HIGHLIGHT SPECIFIC MOUNTING DETAILS | | | AND ANCHORS TO BE USED. | | | 8-ARCHITECT/ENGINEER TO PROVIDE THE | | | DESIGN PRESSURES AT ALL EXTERIOR | | | OPENINGS. | | | 9-SPECIFY CONSTRUCTION AT FRONT AND REAR | | | PORCH CEILINGS AS PER SEC 2504.2 SBC | | | 1997. | | | 10-PROVIDE TWO COPIES OF ENGINEERED ROOF | | | TRUSSES SIGNED AND SEALED. | | | NOTE:TRUSS LAYOUT NEEDS TO BE SIGNED | | | AND SEALED BY TRUSS ENGINEER TOO. |
|