| Plan Review Notes For Permit 99071192 |
| Permit Number |
99071192 |
|
| Review Stop |
P |
| Sequence Number |
4 |
|
| Notes |
| Date |
Text |
| 2001-01-08 00:00:00 | REVISED SANITARY RISER:FIXTURE DRAINS | | | DOWNSTREAM OF WATER CLOSETS SHALL BE | | | VENTED PER SPC SEC.913.2. | | | | | | REVISION SHALL BE SIGNED AND SEALED PER | | | COUNTYWIDE AMENDMENTS TO STANDRD PLBG. | | | CODE SEC.104.2.3. | | | | | | THE SUBMITTED RISER DIAGRAM DOESN'T | | | MATCH THE DIAGRAM ON THE APPROVED PLANS. |
|