| Plan Review Notes For Permit 99070071 |
| Permit Number |
99070071 |
|
| Review Stop |
R |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2001-01-08 00:00:00 | APPROVED WITH PROVISO: | | | 1-PROVIDE TRUSS DWGS SIGNED AND SEALED, | | | INCLUDING THE TRUSS LAYOUT.SEC 104.2.2 | | | CITY AMENDMENTS. | | | DESIGNER OF RECOR TO REVIEW ALL TRUSS | | | DWGS PRIOR TO SUBMITTAL TO THIS OFFICE | | | 2-ENTRY DOOR TO HAVE 32"MIN.CLEAR OPEN'G | | | TABLE 1004 SBC 1997. | | | 3-PROVIDE SAFETY GLASS AT GUEST BATH. | | | SEC 2405.2 SBC 1997. | | | 4-GAS APPLIANCES IN GARAGE.SPECIFY HOW | | | TO COMPLY WITH SEC. 402.7 SGC 1997. | | | 5-FOOTING F2 TO BE 16"MIN. DEEP AS PER | | | 1804.1.3SBC/97 & 1804.1.9 CITY AMENDME | | | 6-PROVIDE THE DESIGN PRESSURES AT ALL | | | EXTERIOR OPENINGS.SEC. 1606 SBC 1997. | | | 7-PROVIDE PRODUCT APPROVAL FOR ENTRY | | | DOORS, HORIZONTAL WINDOWS,MULLIONS FOR | | | TRANSOMS ABOVE SLIDING GLASS DOORS, | | | ROUND WINDOWS. | | | 8-SEE PLANS FOR ADDITIONAL COMMENTS. | | | | | | NOTE: | | | REVISE ORIGINAL DRAWINGS AS REQUIRED. | | | ALSO, ALL NOTES AND SPECIFICATIONS NEED | | | TO BE UPDATED TO 1997 SBC. |
|