Plan Review Notes
Plan Review Notes For Permit 99061270
Permit Number 99061270
Review Stop R
Sequence Number 1
Notes
Date Text
2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-PROVIDE TRUSS DWGS SIGNED AND SEALED,
 INCLUDING THE TRUSS LAYOUT.SEC 104.2.2
 CITY AMENDMENTS.
 DESIGNER OF RECORD TO REVIEW ALL TRUSS
 DWGS PRIOR TO SUBMITTAL TO THIS OFFICE
 2-ENTRY DOOR TO HAVE 32"MIN.CLEAR OPEN'G
 TABLE 1004 SBC 1997.
 3-PROVIDE SAFETY GLASS AT GUEST BATH
 SEC. 2405.2 SBC 1997.
 4-GAS APPLIANCES IN GARAGE: SPECIFY HOW
 TO COMPLY WITH SEC. 402.7 SGC 1997.
 5-FOOTING F2 TO BE 16" MIN. DEEP AS PER
 1804.1.3 SBC/97 & 1804.1.9 CITY AMENDM
 6-PROVIDE THE DESIGN PRESSURES AT ALL
 EXTERIOR OPENINGS.SEC. 1606 SBC 1997.
 7-PROVIDE PRODUCT APPROVAL FOR ENTRY
 DOORS, HORIZONTAL WINDOWS,MULLIONS FOR
 TRANSOMS ABOVE SLIDING GLASS DOORS,
 ROUND WINDOWS.
 8-SEE PLANS FOR ADDITIONAL COMMENTS.
  
 NOTES:
 A-REVISE ORIGINAL DRAWINGS AS REQUIRED.
 ALSO, ALL NOTES AND SPECIFICATIONS
 NEED TO BE UPDATED TO 1997 SBC.
 B-GENERAL NOTES ON SHEET A-7 ARE NOT
 LEGIBLE.