| Plan Review Notes For Permit 99060891 |
| Permit Number |
99060891 |
|
| Review Stop |
R |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2001-01-08 00:00:00 | APPROVED WITH PROVISO: | | | 1-PROVIDE TRUSS DWGS SIGNED AND SEALED, | | | INCLUDING THE TRUSS LAYOUT. | | | DESIGNER OF RECORD TO REVIEW ALL TRUSS | | | DWGS PRIOR TO SUBMITTAL TO THIS OFFICE | | | 2-ENTRY DOOR TO HAVE 32"MIN.CLEAR OPEN'G | | | TABLE 1004 SBC 1997 | | | 3-PROVIDE SAFETY GLASS AT GUEST BATH | | | SEC 2405.2 SBC 1997 | | | 4-GAS APPLIANCES IN GARAGE. SPECIFY HOW | | | TO COMPLY WITH SEC 402.7 SGC 1997 | | | 5-FOOTING F2 TO BE 16" MIN. DEEP. AS PER | | | 1804.1.3 SBC/97 & 1804.1.9 CITY AMENDM | | | 6-PROVIDE THE DESIGN PRESSURES AT ALL | | | EXTERIOR OPENINGS. SEC 1606 SBC 1997 | | | 7.PROVIDE PRODUCT APPROVAL FOR ENTRY | | | DOORS,HORIZONTAL WINDOWS, MULLIONS FOR | | | TRANSOMS ABOVE SLIDING GLASS DOORS, | | | ROUND WINDOWS. | | | 8-SEE PLANS FOR ADDITIONAL COMMENTS |
|