| Plan Review Notes For Permit 99040251 |
| Permit Number |
99040251 |
|
| Review Stop |
B |
| Sequence Number |
7 |
|
| Notes |
| Date |
Text |
| 2001-01-08 00:00:00 | PRODUCT APPROVALS CHECKLIST: | | | 1-APARTMENT ENTRY DOORS: | | | A) DOORS MUST BE LABELED WITH THE | | | REQUIRED FIRE RATING (20 MINUTES). | | | SEC. 705.1.3.2 SBC 1994. | | | B) DOORS SHALL BE SELF-CLOSING. | | | SEC. 705.1.3.2.3 SBC 1994. | | | | | | 2-ALUMINUM SINGLE HUNG WINDOW PRODUCT | | | APPROVAL IS MISSING PAGE 2C. | | | | | | 3-ALUMINUM TUBE MULLION PRODUCT APPROVAL | | | REQUIRES ARCHITECT OR ENGINEER TO | | | SELECT THE PROPER MULLION CHART AND | | | ANCHORS WHICH MEET OR EXCEED THE | | | DESIGN LOADING CONDITIONS. | | | SEE NOTE #3 OF GENERAL NOTES OF DADE | | | COUNTY APPROVED DRAWINGS. | | | | | | 4-ALL SUBMITTALS TO BE REVIEWED BY | | | ENGINEER AND ARCHITECT OF RECORD | | | RESPECTIVELY, PRIOR TO SUBMITTAL TO | | | THIS OFFICE. |
|