| Plan Review Notes For Permit 99040081 |
| Permit Number |
99040081 |
|
| Review Stop |
P |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2001-01-08 00:00:00 | CLEARLY NOTE SLOPE OF PIPE FOR 6" SD | | | LINE FROM SLOT DRAINS.(SEE 4TH.FLR LEVEL | | | AND CHECK ALL OTHER LEVELS.)COMPLY W/ | | | TABLE 1108.2 OF SPC. | | | | | | SHT.P5.01-SQ.FOOT AREA DRAINED BY SLOT | | | DRAINS DOESN'T CORRELATE W/SHTS.P3.01 & | | | P3.02.COMPLY W/TABLE 1108.2 OF SPC. | | | | | | NOTE:SUBMITTED REVISIONS ENCOMPASS | | | CHANGES TO THE STORM DRAINAGE SYSTEM. |
|