| Plan Review Notes For Permit 99030676 |
| Permit Number |
99030676 |
|
| Review Stop |
E |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2001-01-08 00:00:00 | ***********UNSAT*********************** | | | | | | 1)NOTE: NEED LOAD CALCULATIONS AS PER | | | 220-3-D-1 | | | 2)NOTE: NEED TO SHOW SIZE OF EXISTING | | | SERVICE TO INCLUDE SERVICE WIRE SIZE. | | | 3)NOTE: NEED TO SHOW NEW PANEL SCHEDULE | | | FOR ADDITION OF NEW CIRCUTS TO EXISTING | | | PANEL. DINING AREA REQ`S 20 AMP BRANCH | | | CIRCUTS AS PER CODE. | | | 4)NOTE: ALSO AS PER 210-52D BATH REC IS | | | TO ON IT`S OWN 20 AMP BRANCH CIRCUT. | | | 5)NOTE: PLEASE SHOW EXISTING LOCATION | | | OF REC AT REAR OF RESIDENCE AS REQ`D BY | | | 210-52 E IF NO REC EXIST THEN ONE NEEDS | | | TO BE ADDED TO REAR OF ADDITION. | | | 6)NOTE: NEED TO HAVE SMOKE DETECTORS | | | INSIDE AND OUTSIDE ALL NEW BEDROOMS | | | AS REQ`D BY NFPA-72 2-2.1.1.1 1993/1996 | | | EDDITION. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION | | | FOR REVIEW AND APPROVAL. IF THERE ARE | | | ANY QUESTIONS OR I CAN BE OF ANY ASST. | | | PLEASE CONTACT ME AT 659-8096 EXT8372 |
|