Plan Review Notes
Plan Review Notes For Permit 23070502
Permit Number 23070502
Review Stop B
Sequence Number 1
Notes
Date Text
2023-07-28 13:56:44REVISION
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE SHOW THE ACCESSIBLE PARKING TO BE ON THE
 SHORTEST ROUTE TO THE BUILDING ENTRY - FBC A 208.3
  
 2) PLEASE SHOW THE ACCESSIBLE ROUTE FROM THE ACCESSIBLE
 PARKING SPACE TO THE BUILDING ENTRY TO BE 44" WIDE -
 FBC A 208.3
  
 3) DRAWING A6.3.1 SHOWS A DOOR SWING OVER THE STEPS -
 PLEASE SHOW THE DOOR LANDING WIDTH AND LENGTH TO COMPLY
 WITH FBC 1010.1.6 LANDINGS SHALL HAVE A LENGTH MEASURED
 IN THE DIRECTION OF TRAVEL OF NOT LESS THAN 44 INCHES
 (1118 MM).
  
 4) DRAWING A9.2.3 AND A9.2.1 SHOW A TOILET SEAT COVER
 DISPENSER MOUNTED BEHIND OR ON TOP OF THE GRAB BAR -
 PLEASE SHOW THAT THE GRAB BAR CLEARANCES ARE MAINTAINED
 PER FBC 609.3 SPACING.
 THE SPACE BETWEEN THE WALL AND THE GRAB BAR SHALL BE
 11/2 INCHES (38 MM). THE SPACE BETWEEN THE GRAB BAR AND
 PROJECTING OBJECTS BELOW AND AT THE ENDS SHALL BE 11/2
 INCHES (38 MM) MINIMUM. THE SPACE BETWEEN THE GRAB BAR
 AND PROJECTING OBJECTS ABOVE SHALL BE 12 INCHES (305
 MM) MINIMUM.


Account Summary | Usage Policy | Privacy Policy