| Date |
Text |
| 2023-06-30 12:53:01 | REMODEL |
| | REVIEWED BY ROGER MCPHERSON |
| | 561-805-6716 |
| | [email protected] |
| | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 |
| | AMENDMENT |
| | |
| | CORRECTIONS NEEDED - |
| | |
| | THE PALM BEACH COUNTY MAP SHOWS THAT THE BUILDING IS IN |
| | A FLOOD ZONE (AE6). |
| | |
| | PLEASE PROVIDE A COST BREAK DOWN FOR THE ENTIRE |
| | ALTERATION. THE TOTAL JOB COST WILL BE NEEDED TO |
| | DETERMINE IF THE COMPLETE ALTERATION IS A SUBSTANTIAL |
| | IMPROVEMENT. FBC E 701.3 FLOOD HAZARD AREAS. |
| | IN FLOOD HAZARD AREAS, ALTERATIONS THAT CONSTITUTE |
| | SUBSTANTIAL IMPROVEMENT SHALL REQUIRE THAT THE BUILDING |
| | COMPLY WITH SECTION 1612 OF THE FLORIDA BUILDING CODE, |
| | BUILDING, OR SECTION R322 OF THE FLORIDA BUILDING CODE, |
| | RESIDENTIAL, AS APPLICABLE. |
| | |
| | FBC EXISTING BUILDING 202 - SUBSTANTIAL IMPROVEMENT. |
| | FOR THE PURPOSE OF DETERMINING COMPLIANCE WITH THE |
| | FLOOD PROVISIONS OF THIS CODE, ANY REPAIR, ALTERATION, |
| | ADDITION, OR IMPROVEMENT OF A BUILDING OR STRUCTURE, |
| | THE COST OF WHICH EQUALS OR EXCEEDS 50 PERCENT OF THE |
| | MARKET VALUE OF THE STRUCTURE, BEFORE THE IMPROVEMENT |
| | OR REPAIR IS STARTED. |
| | |
| | IF THE JOB IS A SUBSTANTIAL IMPROVEMENT THE FINISHED |
| | FLOOR OF THE HOUSE WILL NEED TO BE 2 FEET ABOVE THE |
| | BASE FLOOD ELEVATION OF 6 FOOT PER CITY ORDINANCE - |
| | 4729-17 SEC. 18-33 - TECHNICAL AMENDMENTS TO FLORIDA |
| | BUILDING CODE, RESIDENTIAL. (A) R322.2.1 (1) |
| | |
| | A SURVEY COULD BE USED TO SHOW IF THE FINISHED FLOOR |
| | ELEVATION OF THE HOUSE IS ALREADY AT 8.00 NAVD |
| | |
| | |