2023-07-24 16:23:35BUILDING REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #23060889
 809 S FLAGLER DR
  
 NOTE:
 LEVEL 1 ALTERATION. SEC. 602 FBC-EXISTING BUILDING.
 SEC. 702.6 FBC-EXISTING BUILDING. ALL NEW WORK SHALL
 COMPLY WITH THE MATERIALS AND METHODS REQUIREMENTS IN
 THE FLORIDA BUILDING CODE.
  
 1-THIS BUILDING IS LOCATED IN A AE FLOOD ZONE WITH A
 BASE FLOOD ELEVATION (BFE) OF 6 FEET BASED ON NAVD 88.
 THE PROPOSED WORK IS CONSIDERED A SUBSTANTIAL
 IMPROVEMENT. THE BUILDING SHALL HAVE THE LOWEST FLOOR
 FINISHED ELEVATION ELEVATED TO OR ABOVE THE BASE FLOOD
 ELEVATION PLUS TWO FEET. THEREFORE, THE MIN. REQUIRED
 FINISHED FLOOR ELEVATION IS 8 FEET.
 NOTE: PROVIDE SIGNED AND SEALED FLOOD HAZARD
 DOCUMENTATION AS REQUIRED BY SEC. 1612.5 FBC-BUILDING
 SHOWING COMPLIANCE. PLANS NEED TO SHOW THE FINISHED
 FLOOR ELEVATION. ALSO, NEED TO PROVIDE THE ELEVATION
 CERTIFICATE AND SURVEY SHOWING THE ELEVATIONS FOR
 VERIFICATION.
 CITY ORDINANCE 4729-17.
 SEC. 18-33 TECHNICAL AMENDMENTS TO FLORIDA BUILDING
 CODE.
 SEC. 107.3.5.3 CITY AMENDMENTS.
  
 NOTE:
 COORDINATE WITH CITY HISTORIC PRESERVATION IF HISTORIC
 VARIANCE MAY BE APPLIED FOR AND BUILDING MAY RETAIN THE
 HISTORIC VALUE AFTER THE ALTERATION.
  
 2- REVISE CODIFICATION INFORMATION ON SHEET CVR:
 A)REVISE CODE INFORMATION. PLANS NEED TO BE DESIGNED
 BASED ON ASCE 7-16 NOT ASCE 7-10. REVISE AS REQUIRED.
 NOTE: THIS APPLIES TO ALL DRAWINGS SUBMITTED WITH THE
 REFERENCING ASCE-10. REVISE ALL PLANS.
  
 B)CLEARLY SPECIFY TYPE OF CONSTRUCTION. SEE SEC. 602
 FBC-BUILDING FOR CORRESPONDING CONSTRUCTION
 CLASSIFICATION AND SPECIFY ON PLANS.
  
 C)BUILDING EXPOSURE IS INCORRECT. THIS BUILDING IS
 LOCATED IN EXPOSURE D NOT C. REVISE AS REQUIRED. SEC.
 1609.4 FBC-BUILDING.
  
 D)SPECIFY THE NOMINAL WIND SPEED AS REQUIRED BY SEC.
 1603.1.4 FBC-BUILDING.
  
 E)PROVIDE THE COMPONENTS AND CLADDING WIND PRESSURE AS
 REQUIRED BY SEC. 1603.1.4 FBC-BUILDING.
  
 F)SPECIFY THE INTERNAL PRESSURES COEFFICIENT AS
 REQUIRED BY SEC. 1603.1.4 FBC-BUILDING.
  
 3- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR WALL
 FLASHING AT ALL EXTERIOR OPENINGS. SEC. 1405.4
 FBC-BUILDING.
  
 4- ENGINEER OF RECORD TO PROVIDE COMPLETE
 DETAILS/SPECIFICATIONS FOR WELDING OF THE DESIGNED
 SUPPORT ASSEMBLY TO RECEIVE NEW WINDOWS. SPECIFY
 WELDING AT ALL HORIZONTAL AND VERTICAL ALUMINUM FRAMING
 MEMBERS, INCLUDING ALUMINUM SILL PLATE SPECIFIED ON
 SOME WINDOWS. SEC. 107.2.1.3 CITY AMENDMENTS.
  
 5- PROVIDE CURRENT PRODUCT APPROVAL FOR WINDOWS TO BE
 INSTALLED. FLORIDA PRODUCT APPROVAL FL21334-R2
 SUBMITTED WAS REVISED FOR FL21334-R4.
 FAC 61G20-3.001.
  
 6- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) WINDOW PRODUCT APPROVAL AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 7- PROVIDE COMPLETE SITE SPECIFIC WINDOW INSTALLATION
 INFORMATION AS REQUIRED BY THE LIMITATIONS OF USE ON
 PAGE 1 OF 11 OF PANEL WALLS PRODUCT APPROVAL FL21334
 SUBMITTED. SPECIFY ALL FRAMING MEMBERS AND CONNECTORS
 TO THE SUPPORT ASSEMBLY. SEC. 107.2.1 CITY AMENDMENTS.
 SEC. 1609.1 FBC-BUILDING.
  
 8- DIGITAL SIGNATURE COMMENTS:
 A)DRAWINGS HAVE AN ENGINEER'S SELF-CERTIFIED DIGITAL
 SIGNATURE. ENGINEER CANNOT SELF-CERTIFY THE DIGITAL
 SIGNATURE. THIRD PARTY CERTIFICATION IS REQUIRED BY FAC
 61G15-23.004. (NOTE: ENGINEER TO CONTACT THE BOARD OF
 ENGINEER'S FOR SELF-CERTIFIED DIGITAL SIGNATURE
 QUESTIONS).
  
 B)ENGINEER'S DIGITAL SIGNATURE DOESN'T COMPLY WITH THE
 REQUIREMENTS OF FBPE. NEED A SEPARATE TEXT BOX WITH THE
 TEXT BOX LANGUAGE IDENTICAL TO THE SAMPLES SHOWN BY
 FBPE.
 SEE FBPE.ORG/LEGAL/SIGNING-AND-SEALING-ENGINEERING-DOCU
 MENTS/ AND REVISE DIGITAL SIGNATURE AS REQUIRED.
 NOTE: THIS WAS CONFIRMED WITH THE FBPE INVESTIGATOR.
  
 SEC. 61G15-23.004 F.A.C. PROCEDURES FOR DIGITALLY
 SIGNING AND SEALING ELECTRONICALLY TRANSMITTED PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND
 HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE
 REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  