| Plan Review Notes For Permit 23060841 |
| Permit Number |
23060841 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2023-07-17 09:21:00 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II/INSPECTOR | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | 2ND BUILDING REVIEW DENIED: | | | | | | 1.) FBC B 107.2.1, PLEASE INDICATE WITHIN THE NOA | | | #21-1208.11(ARMOR SCREEN) WHICH OPTIONS WILL BE USED. | | | | | | 2.) FBC B 107.2.1, SUBMIT THE PRODUCT APPROVAL FOR THE | | | ACCORDIAN SHUTTERS AND INDICATE WITHIN THE PRODUCT | | | APPROVAL WHICH OPTIONS WILL BE USED. | | | | | | 3.) FBC B 107.2.1, PLEASE SUBMIT A SCHEDULE FOR THE | | | SHUTTER & ARMOR SCREEN OPENINGS. | | | SPECIFY THE OPENING SIZE, THE WIND PRESSURES, TYPE OF | | | ANCHOR, ANCHOR SPACING, EDGE DISTANCE, PANEL LENGTH, | | | PANEL SPAN, SEPARATION DISTANCE FROM PANEL TO GLASS AND | | | THE APPLICABLE SECTION NUMBER FROM THE INSTALLATION | | | DRAWINGS. PLEASE CONTACT ME IF YOU NEED A BLANK CITY OF | | | WEST PALM BEACH SCHEDULE FOR OPENINGS. |
|