| | 1ST REVIEW: FBC 2020 7TH EDITION |
| | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) |
| | FBC B = FBC BUILDING |
| | FBC R = FBC RESIDENTIAL |
| | FBC EB = FBC EXISTING BUILDING |
| | FBC A = FBC ACCESSIBILITY |
| | FBC EC = FBC ENERGY CONSERVATION |
| | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT |
| | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. |
| | |
| | 1. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL14317-R12 |
| | HAS BEEN REVISED TO FL14317-R14. PLEASE PROVIDE A |
| | COMPLETE SET; IT COVERS MULTIPLE PRODUCT TYPES; ROOF |
| | COVER OPTIONS; ALLOWABLE UNDERLAYMENT/TILE-ADHESIVE |
| | COMBINATIONS & ALLOWABLE SUBSTRATES. SELECT ALL |
| | APPLICABLE OPTIONS FROM EACH CATEGORY. SELECT |
| | ATTACHMENT LIMITATION SYSTEM USED FROM 5.8.3.1 |
| | DIRECT-TO-DECK PAGES #4 OR #5. SYSTEM SELECTED MUST |
| | MEET OR EXCEED -78 MAXIMUM DESIGN PRESSURE. ALL |
| | APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY |
| | IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. |
| | 2. FBC R 301 FAC9N-3. MECHANICAL TILE INSTALLATION. |
| | PLEASE PROVIDE TABLE 3, PAGE #31 MECHANICAL FASTENING |
| | FOR CONCRETE AND CLAY TILES OF THE FLORIDA HIGH WIND |
| | CONCRETE AND CLAY TILE INSTALLATION MANUEL 6TH EDITION. |
| | PLEASE INDICATE (HIGHLIGHT/CIRCLE) THE FOLLOWING: DECK |
| | THICKNESS; METHOD; FASTENER TYPE; ATTACHMENT |
| | DESCRIPTION; LOW, MEDIUM OR HIGH USING TABLE 2 HC PAGE |
| | #26 OF THE FLORIDA HIGH WIND CONCRETE AND CLAY TILE |
| | INSTALLATION MANUEL 6TH EDITION. ALL APPLICABLE DETAILS |
| | AND ATTACHMENTS MUST BE CLEARLY IDENTIFIED. REQUIRED IF |
| | THE MECHANICAL FASTENING RESISTANCE VALUES ARE NOT |
| | LISTED IN THE PRODUCT APPROVAL/NOA. |
| | 3. FBC B 107.2.1 FOR CLARITY PLEASE PROVIDE A ROOF |
| | DIAGRAM/SKETCH WITH THE AREAS TO RECEIVE NEW ROOFING |
| | CLEARLY IDENTIFIED ON DRAWING; INCLUDE ROOF SLOPE(S), |
| | MEAN ROOF HEIGHT(S). FLAT/LOW SLOPE ROOFS MUST SHOW |
| | POSITIVE DRAINAGE. |
| | 4. FBC R 301 FAC9N-3. PROVIDE A COMPLETE SET OF 2020 |
| | CODE VERSION PRODUCT APPROVALS/NOA'S FOR THE PROPOSED |
| | HIP & RIDGE TILE ADHESIVE TO BE USED. |
| | 5. WPB A 109.3 BUILDING PERMIT VALUATIONS APPEARS TO BE |
| | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE |
| | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, |
| | QUANTITY ESTIMATES. VALUE TO INCLUDE LABOR AND |
| | MATERIALS, ARCHITECTURAL AND DESIGN FEES, OVERHEAD AND |
| | PROFIT. |
| | |