| 2023-06-05 15:30:32 | RESIDENTIAL (R3) RE-ROOF SECOND BUILDING REVIEW |
| | COMMENTS |
| | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. |
| | PERMIT #23051022 |
| | 333 MURRAY RD |
| | |
| | 1- ACCORDING TO PALM BEACH COUNTY PROPERTY APPRAISER, |
| | THE VALUE OF THE STRUCTURE IS MORE THAN $300,000. NEED |
| | TO COMPLY WITH THE ROOF TO WALL CONNECTIONS AS REQUIRED |
| | BY SEC. 706.8 FBC-EXISTING BUILDING. PROVIDE COMPLETE |
| | INFORMATION SHOWING COMPLIANCE WITH THE ROOF TO WALL |
| | CONNECTIONS. |
| | NOTE: A SEPARATE SUB-PERMIT IS REQUIRED FOR ROOF TO |
| | WALL CONNECTIONS. THIS WORK CAN NOT BE DONE BY THE |
| | ROOFING CONTRACTOR UNLESS ROOFING CONTRACTOR POSSESSES |
| | THE PROPER LICENSE TO PERFORM THIS WORK. |
| | |
| | RESPONSE: |
| | GENERAL CONTRACTOR "NEW ROOF INSTALLATION" LETTER: |
| | A) CONTRACTOR NEEDS TO SHOW IN DETAIL WHAT DOES THE |
| | COST OF $10,732 COVERS FOR ROOF TO WALL CONNECTIONS |
| | REQUIRED BY SEC. 706.8 FBC-EXISTING BUILDING. |
| | NOTE: THE 15 PERCENT EXCEPTION APPLIES ONLY IF THE |
| | EVALUATION AND INSTALLATION OF CONNECTIONS AT GABLE |
| | ENDS OR ALL CORNERS CANNOT BE COMPLETED FOR 15 PERCENT |
| | OF THE COST OF ROOF REPLACEMENT. SEE SEC. 706.8 |
| | FBC-EXISTING BUILDING. |
| | |
| | B) CONTRACTOR NEEDS TO SIGN THE LETTER. |
| | SEC. 107.2.1 CITY AMENDMENTS. |
| | |
| | 2- FLAT ROOF FL16717-R13 SUBMITTED. |
| | SELECTED ASSEMBLY W-107 ON PAGE 22 OF 87 DOESN'T MEET |
| | THE DESIGN PRESSURES FOR ALL ROOF ZONES. PROVIDE SIGNED |
| | AND SEALED RAS 117 CALCULATIONS FOR NAIL ENHANCING AT |
| | PERIMETER AND CORNER AREAS AS REQUIRED BY LIMITATION |
| | 5.7.2 ON PAGE 5 OF 5 OR SELECT ANOTHER ASSEMBLY THAT |
| | MEETS THE DESIGN PRESSURES FOR ALL ROOF ZONES. |
| | |
| | RESPONSE: |
| | REPEAT COMMENT. NOT ADDRESSED. |
| | NOTE: SEE FLAT ROOF LOCATED ON THE SECOND FLOOR. |
| | CLEARLY SPECIFY THE HEIGHT OF ALL ROOFS. SEC. 107.2.1 |
| | CITY AMENDMENTS. SEC. R301.2.1 FBC-RESIDENTIAL. |
| | |
| | 3- ROOF TILE NOA 22-0714.18 AND ROOF TILE ADHESIVE |
| | FL6332-R9 SUBMITTED: CLEARLY MARK ADHESIVE PADDY SIZE |
| | TO BE USED AS REQUIRED BY CITY POLICY FOR ALL ROOFING |
| | PERMITS TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES |
| | OF SEC R301.2.1 FBC-RESIDENTIAL. |
| | |
| | RESPONSE: |
| | REPEAT COMMENT. NOT ADDRESSED. |
| | |
| | 4- TU PLUS FLORIDA PRODUCT APPROVAL FL-5259-R38 |
| | SUBMITTED SAYS "PENDING FBC APPROVAL". NEED TO PROVIDE |
| | APPROVED PRODUCT APPROVAL. |
| | F.A.C. 61G20.3.001. |
| | |
| | RESPONSE: |
| | REPEAT COMMENT. NOT ADDRESSED. |
| | |
| | 5- HIP AND RIDGE TILE INSTALLATION. PROVIDE COMPLETE |
| | DETAILS AND SPECIFICATIONS FOR HIP AND RIDGE |
| | INSTALLATION AS REQUIRED BY SEC. R905.3.7.1 |
| | FBC-RESIDENTIAL. PROVIDE SPECIFICATIONS IN ACCORDANCE |
| | WITH FRSA/TRI FLORIDA HIGH WIND CONCRETE AND CLAY TILE |
| | INSTALLATION MANUAL (6TH EDITION) OR THE |
| | RECOMMENDATIONS OF RAS 118, 119 OR 120. |
| | ALTERNATIVE: IF USING METAL SUPPORT, THEN PROVIDE |
| | PRODUCT APPROVAL FOR HIP AND RIDGE METAL SUPPORT AND |
| | CLEARLY MARK ATTACHMENT METHOD. |
| | |
| | RESPONSE: |
| | REPEAT COMMENT. NOT ADDRESSED. |
| | |
| | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| | QUESTIONS REGARDING THESE COMMENTS, |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |
| | |
| | |
| | |