| Plan Review Notes For Permit 23050025 |
| Permit Number |
23050025 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2023-06-30 16:10:59 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT- 23050025 | | | 6/30/23 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET A-5: PLEASE REFER TO SEC. 810.1 FBC EX AND | | | PROVIDE THE EXISTING OCCUPANT LOAD OF THE FLOOR AND THE | | | INCREASED OCCUPANT LOAD BASED ON THE OFFICE CONVERSION | | | TO NEW CLASSROOM. PLEASE NOTE IF THE EXISTING LOAD | | | INCREASES BY MORE THAN 20%, PLUMBING FIXTURES SHALL BE | | | PROVIDED IN COMPLIANCE WITH TABLE 403.1 FBC P. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|