| Date |
Text |
| 2023-07-05 09:40:49 | PERMIT- 23050007 |
| | 7.5.2023 |
| | |
| | CODES IN EFFECT: |
| | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 |
| | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| | FHDA- FAIR HOUSING DESIGN ACT MANUAL |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | |
| | |
| | 1. [FBC 1207.3] STRUCTURE-BORNE SOUND. FLOOR/CEILING |
| | ASSEMBLIES |
| | BETWEEN DWELLING UNITS AND SLEEPING UNITS OR BETWEEN A |
| | DWELLING |
| | UNIT OR SLEEPING UNIT AND A PUBLIC OR SERVICE AREA |
| | WITHIN |
| | THE STRUCTURE SHALL HAVE AN IMPACT INSULATION CLASS |
| | RATING OF |
| | NOT LESS THAN 50, OR NOT LESS THAN 45 IF FIELD TESTED, |
| | WHEN TESTED |
| | IN ACCORDANCE WITH ASTM E492. |
| | |
| | 2. [FBC 603.1] ALLOWABLE MATERIALS IN NON-COMBUSTIBLE |
| | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL |
| | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID |
| | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED |
| | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE |
| | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 |
| | OR UL 723. |
| | |
| | WHISPERMAT CS IS UNIQUELY APPROVED FOR TILE USE. THIS |
| | TYPE OF UNDERLAYMENT WILL NOT BE APPROVED FOR |
| | ENGINEERED WOOD AS INDICATED ON YOUR PLANS. |
| | PROVIDECORRECT UNDERLAYMENT APPROVED FOR THIS TYPE OF |
| | INSTALLATION. WHISPERMAT HW OR SIMILAR RECOMMEDED. |
| | |
| | 3. FBC [A]109.1 VALUE : ITEMIZED THE COST OF MATERIAL |
| | AND LABOR BY A PROFESSIONAL FLORIDA LICENSED CONTRACTOR |
| | TO DO THIS INSTALLATION AND ADJUST THE VALUE OF THIS |
| | PERMIT ON YOUR APPLICATION. |
| | |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | |
| | |
| | LOUIS BOND, AIA |
| | BUILDING PLANS EXAMINER II |
| | DEVELOPMENT SERVICES DEPT. |
| | BUILDING DIVISION |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH, FLORIDA 33401 |
| | PH: 561-805-6729 |
| | FX: 561-805-6676 |