2023-05-25 17:55:07RESIDENTIAL (R3) REROOF BUILDING REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #23050002
 717 MADDOCK ST
  
 NOTE:
 LEVEL 1 ALTERATION. SEC. 602 FBC-EXISTING BUILDING.
 SEC. 702.6 FBC-EXISTING BUILDING. ALL NEW WORK SHALL
 COMPLY WITH THE MATERIALS AND METHODS REQUIREMENTS IN
 THE FLORIDA BUILDING CODE.
  
 1- FLAT ROOF INSTALLATION IS NOT CLEAR. CERTAINTEED
 MODIFIED BITUMEN NOA 20-0723.29 SUBMITTED WAS MARKED
 WITH 3 DIFFERENT ASSEMBLIES AND CONTRACTOR ALSO
 SUBMITTED SIGNED AND SEALED NAIL ENHANCEMENT
 CALCULATIONS. CONTRACTOR NEEDS TO SUBMIT ONLY ONE
 OPTION TO AVOID CONFLICTS/DELAYS.
 IF USING THE NOA ALONE WITHOUT ENGINEERING, THEN
 CONTRACTOR NEEDS TO SELECT ONLY ONE ASSEMBLY THAT MEETS
 THE DESIGN PRESSURES FOR ALL ROOF ZONES (NOTE: ONLY
 MARKED ASSEMBLY SYSTEM TYPE E(24) ON PAGE 47 OF 48 WILL
 MEE THE DESIGN PRESSURE FOR ALL ROOF ZONES. RESUBMIT AS
 REQUIRED WITH ONLY ONE OPTION MARKED.
  
 ON THE OTHER HAND IF USING THE SIGNED AND SEALED
 CALCULATIONS , THEN THE FOLLOWING NEEDS TO BE
 ADDRESSED.
 A)ENGINEER NEEDS TO PROVIDE SKETCH SHOWING HOW THE SIX
 STAGGERED ROWS OF NAILS ARE GOING TO BE INSTALLED IN
 THE FIELD OF THE SHEET FOR ZONE 2 AND HOW THE SEVEN
 STAGGERED ROWS OF NAILS ARE GOING TO BE INSTALLED IN
 THE FIELD OF THE SHEET FOR ZONE 3. (NOTE: CHECK RAS 117
 SEC. 8.1 FOR MINIMUM FASTENER SEPARATION).
  
 B)CALCULATIONS SUBMITTED HAVE A COPY OF THE ENGINEER'S
 SEAL/SIGNATURE. NEED ORIGINAL SEAL/SIGNATURE WHEN
 SUBMITTED FOR PUBLIC RECORDS. SEC. 471 F.S.
 NOTE: ELECTRONIC SUBMITTALS NEED VERIFIABLE DIGITAL
 SIGNATURE.
  
 ENGINEERS
 61G15-23.004. F.A.C. PROCEDURES FOR DIGITALLY SIGNING
 AND SEALING ELECTRONICALLY TRANSMITTED PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
  
 2- POLYGLASS UNDERLAYMENT NOA 21-1217.02 SUBMITTED.
 CLEARLY MARK WHICH SYSTEM TYPE ON PAGE 4 OF 7 IS GOING
 TO BE INSTALLED. SEC. 107.2.1 CITY AMENDMENTS.
  
 3- OWENS HIP & RIDGE SHINGLES NOA 20-0812.09 EXPIRED ON
 02/28/23. NEED CURRENT PRODUCT APPROVAL.
 F.A.C. 61G20.3.001.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  