Plan Review Notes
Plan Review Notes For Permit 23041442
Permit Number 23041442
Review Stop NFIP
Sequence Number 1
Notes
Date Text
2023-07-19 14:07:51NFIP REVIEW:
  
 (1)-THE PROPOSED ALTERATION/ADDITION IS GOING TO BE
 BUILT IN A AE FLOOD ZONE WITH A BASE FLOOD ELEVATION
 (BFE) OF 6, 7 AND 8 FEET BASED ON NAVD 88.
 THE PROPOSED WORK IS CONSIDERED A SUBSTANTIAL
 IMPROVEMENT. THE ADDITION AND THE EXISTING HOUSE SHALL
 HAVE THE LOWEST FLOOR FINISHED ELEVATION ELEVATED TO OR
 ABOVE THE BASE FLOOD ELEVATION PLUS TWO FEET.
 NOTE: PLANS (INCLUDING THE FOUNDATION PLAN) NEED TO
 SHOW THE PROPOSED FINISHED FLOOR ELEVATIONS FOR MAIN
 HOUSE AND GARAGES. ALSO, NEED TO PROVIDE THE
 CONSTRUCTION DRAWINGS ELEVATION CERTIFICATE AND SURVEY
 SHOWING THE FINISH FLOOR ELEVATIONS FOR REVIEW.
 CITY ORDINANCE 4729-17.
 SEC. 18-33 TECHNICAL AMENDMENTS TO FLORIDA BUILDING
 CODE.
 SEC. 107.3.5.3 CITY AMENDMENTS.
  
 DURING THE CONSTRUCTION OF THIS STRUCTURE THREE
 DIFFERENT FLOOD ELEVATION CERTIFICATES WILL BE
 REQUIRED:
 (A)CONSTRUCTION DRAWINGS.
 (B)BUILDING UNDER CONSTRUCTION.
 (C)FINISHED CONSTRUCTION.
  