| Date |
Text |
| 2023-05-17 11:05:49 | RESIDENTIAL(R3) RE-ROOF BUILDING REVIEW COMMENTS |
| | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. |
| | PERMIT #23041431 |
| | 2737 S FLAGLER DR |
| | |
| | NOTE: |
| | LEVEL 1 ALTERATION. SEC. 602 FBC-EXISTING BUILDING. |
| | SEC. 702.6 FBC-EXISTING BUILDING. ALL NEW WORK SHALL |
| | COMPLY WITH THE MATERIALS AND METHODS REQUIREMENTS IN |
| | THE FLORIDA BUILDING CODE. |
| | |
| | 1- FLAT ROOF FLORIDA PRODUCT APPROVAL FL2533-R29: |
| | A)CLEARLY MARK WHICH APPROVED ASSEMBLY IS GOING TO BE |
| | INSTALLED TO VERIFY COMPLIANCE WITH THE DESIGN |
| | PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL. |
| | NOTE: PLEASE UPLOAD THE FLORIDA PRODUCT APPROVAL COVER |
| | PAGE AND INSTALLATION INSTRUCTIONS ON THE SAME PDF. |
| | |
| | B)BASED ON OLD FLORIDA PRODUCT APPROVAL FL2533-R28 |
| | SUBMITTED, IT LOOKS LIKE THE PROPOSED ASSEMBLY IS W-68. |
| | NEED TO PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS |
| | AS REQUIRED BY LIMITATION #5.7.2 OF PRODUCT APPROVAL |
| | SUBMITTED. |
| | SEC. 107.2.1 CITY AMENDMENTS. |
| | |
| | 2- HIP AND RIDGE TILE INSTALLATION. PROVIDE COMPLETE |
| | DETAILS AND SPECIFICATIONS FOR HIP AND RIDGE |
| | INSTALLATION AS REQUIRED BY SEC. R905.3.7.1 |
| | FBC-RESIDENTIAL. PROVIDE SPECIFICATIONS IN ACCORDANCE |
| | WITH FRSA/TRI FLORIDA HIGH WIND CONCRETE AND CLAY TILE |
| | INSTALLATION MANUAL (6TH EDITION) OR THE |
| | RECOMMENDATIONS OF RAS 118, 119 OR 120. |
| | ALTERNATIVE: IF USING METAL SUPPORT, THEN PROVIDE |
| | PRODUCT APPROVAL FOR HIP AND RIDGE METAL SUPPORT AND |
| | CLEARLY MARK ATTACHMENT METHOD. |
| | |
| | 3- DESIGNER OF RECORD FOR MASTER PERMIT 23010885 |
| | REFERENCED IN THE PERMIT APPLICATION TO REVIEW AND |
| | APPROVE IN WRITING (NOT SIGNING AND SEALING) ALL |
| | PRODUCT APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY |
| | AMENDMENTS. |
| | |
| | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| | QUESTIONS REGARDING THESE COMMENTS, |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |
| | |