| 2023-06-27 18:51:15 | RESIDENTIAL(R3)REVISION. SIXTH BUILDING REVIEW COMMENTS |
| | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. |
| | REVISION #23041075 |
| | 234 EDGEWOOD DR (MAIN HOUSE ONLY). |
| | |
| | |
| | IMPORTANT: |
| | THIS INFORMATION IS ONLY FOR THE MAIN HOUSE. THERE IS A |
| | SEPARATE PERMIT FOR THE GARAGE. |
| | |
| | |
| | 1- SHUTTERS ARCHITECTURAL DRAWING SIGNED AND SEALED ON |
| | 06/26/2023 SHOWS A FUNCTIONAL SHUTTER NOT A |
| | DECORATIVE-ONLY LOUVERED SHUTTERS. NEED TO PROVIDE A |
| | COMPLETE SHUTTERS INSTALLATION SCHEDULE (SEE CITY |
| | SAMPLE) ALONG WITH A KEY PLAN SHOWING THE OPENINGS |
| | WHERE THE SHUTTERS WILL BE INSTALLED. |
| | SEC. R301.2.1 FBC-RESIDENTIAL. SEC. 107.2.1 CITY |
| | AMENDMENTS. |
| | THIS WAS DISCUSSED WITH ROBERT BROWN (BUILDING |
| | OFFICIAL). SHUTTERS ARE NOT DECORATIVE. THEY ARE |
| | FUNCTIONAL AND NEED COMPLETE INFORMATION. |
| | |
| | NOTE: THERE ARE TWO OPTIONS TO ADDRESS THIS COMMENT. |
| | ONE OPTION IS FOR CONTRACTOR TO SUBMIT SHUTTERS |
| | COMPLETE INSTALLATION SCHEDULE OR THE OTHER OPTION IS |
| | FOR SHUTTERS CONTRACTOR TO SUBMIT ALL THE INFORMATION |
| | UNDER A SEPARATE PERMIT. (PRODUCT APPROVAL, KEY PLAN |
| | AND COMPLETE INSTALLATION SCHEDULE). |
| | CONTRACTOR TO ADVICE IN WRITING HOW ADDRESSING THIS |
| | COMMENT. THE SEPARATE SHUTTERS PERMIT OPTION WILL HELP |
| | TO APPROVE THIS REVISION FASTER. |
| | |
| | 2- NEW COLONIAL SHUTTERS PRODUCT APPROVAL DRAWING |
| | #15-2347 SUBMITTED IS INCOMPLETE. NEED TO PROVIDE |
| | COMPLETE FLORIDA PRODUCT APPROVAL REPORT, INCLUDING THE |
| | FLORIDA PRODUCT APPROVAL COVER PAGE THAT CORRESPONDS TO |
| | THE DRAWINGS SUBMITTED. FAC 61G20.3.001. |
| | NOTE: THE FLORIDA PRODUCT APPROVAL IS REQUIRED BECAUSE |
| | IT SHOWS IF PRODUCT IS APPROVED AND CURRENT CODE IN |
| | EFFECT. CHAPTER 553 F.S. |
| | |
| | 3- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| | (NOT SIGNING AND SEALING) SHUTTERS PRODUCT APPROVAL AS |
| | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. |
| | |
| | 4- SHUTTER DRAWING SUBMITTED HAS A COPY OF THE |
| | ARCHITECT'S SEAL AND SIGNATURE. |
| | IT NEEDS THE ARCHITECT'S DIGITAL SIGNATURE AS DONE WITH |
| | ALL THE MASTER PERMIT DRAWINGS. ALL DOCUMENTS PREPARED |
| | BY A LICENSED ARCHITECT NEED TO HAVE THE ORIGINAL |
| | VERIFIABLE DIGITAL SIGNATURE OF THE ARCHITECT OF RECORD |
| | AS REQUIRED BY SEC. 61G1-16.003 F.A.C. AND CHAPTER 481 |
| | F.S. WHEN SUBMITTING PLANS/DOCUMENTS FOR PUBLIC |
| | RECORDS. |
| | |
| | ARCHITECTS |
| | 61G1-16.005 PROCEDURES FOR DIGITALLY SIGNING AND |
| | SEALING AND FOR ELECTRONICALLY TRANSMITTING PLANS, |
| | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. |
| | |
| | |
| | NOTE: ALL ROOFING PRODUCT APPROVALS ARE REVIEWED UNDER |
| | SEPARATE ROOFING PERMITS. NO NEED TO RESUBMIT UNDER |
| | THIS REVISION TO AVOID CONFLICTS/DELAYS. |
| | |
| | |
| | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| | QUESTIONS REGARDING THESE COMMENTS, |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |
| | |