| Date |
Text |
| 2023-05-18 09:42:24 | REMODEL |
| | REVIEWED BY ROGER MCPHERSON |
| | 561-805-6716 |
| | [email protected] |
| | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 |
| | AMENDMENT |
| | |
| | CORRECTIONS NEEDED - |
| | |
| | 1) DRAWING G1.0 SHOWS THE INCORRECT BUILDING DATA - |
| | UNDER TYPE OF CONSTRUCTION YOU SHOW - UNSPRINKLERED - |
| | UNLIMITED AREA - CANNOT HAVE UNLIMITED AREA AND NO |
| | SPRINKLERS PER FBC 507.3 |
| | |
| | 2) PLEASE SHOW THE ADJACENT OCCUPANCY TYPE AND ANY |
| | REQUIRED FIRE SEPARATION BETWEEN YOU THE ADJACENT |
| | TENNANT - FBC 508.4 |
| | |
| | 3) PLEASE SHOW THE FIRE RATING OF THE STAIR ENCLOSURE |
| | 1011.7.3 ENCLOSURES UNDER INTERIOR STAIRWAYS. |
| | THE WALLS AND SOFFITS WITHIN ENCLOSED USABLE SPACES |
| | UNDER ENCLOSED AND UNENCLOSED STAIRWAYS SHALL BE |
| | PROTECTED BY 1-HOUR FIRE-RESISTANCE-RATED CONSTRUCTION |
| | OR THE FIRE-RESISTANCE RATING OF THE STAIRWAY |
| | ENCLOSURE, WHICHEVER IS GREATER. ACCESS TO THE ENCLOSED |
| | SPACE SHALL NOT BE DIRECTLY FROM WITHIN THE STAIRWAY |
| | ENCLOSURE. |
| | |
| | 4) ACCESSIBLE RESTROOM - ON DRAWING A3.0 - PLEASE SHOW |
| | THE TOILET PAPER HOLDER DIMENSION FROM THE FRONT OF THE |
| | TOILET TO THE CENTER OF THE DISPENSER (NOT TO THE SIDE |
| | AS SHOWN)- FBC A 604.7 DISPENSERS. |
| | TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND |
| | SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230 |
| | MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO |
| | THE CENTERLINE OF THE DISPENSER. |
| | |
| | 5) ACCESSIBLE RESTROOM - ON DRAWING A3.0 - PLEASE SHOW |
| | THE TOILET REAR GRAB BAR LOCATION DIMENSIONS FROM THE |
| | CENTER OF THE TOILET (NOT FROM THE SIDE WALL AS SHOWN) |
| | PER FBC A 604.5.2 REAR WALL. |
| | THE REAR WALL GRAB BAR SHALL BE 36 INCHES (915 MM) LONG |
| | MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER |
| | CLOSET 12 INCHES (305 MM) MINIMUM ON ONE SIDE AND 24 |
| | INCHES (610 MM) MINIMUM ON THE OTHER SIDE. |