Plan Review Notes
Plan Review Notes For Permit 23040920
Permit Number 23040920
Review Stop B
Sequence Number 1
Notes
Date Text
2023-05-18 09:42:24REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) DRAWING G1.0 SHOWS THE INCORRECT BUILDING DATA -
 UNDER TYPE OF CONSTRUCTION YOU SHOW - UNSPRINKLERED -
 UNLIMITED AREA - CANNOT HAVE UNLIMITED AREA AND NO
 SPRINKLERS PER FBC 507.3
  
 2) PLEASE SHOW THE ADJACENT OCCUPANCY TYPE AND ANY
 REQUIRED FIRE SEPARATION BETWEEN YOU THE ADJACENT
 TENNANT - FBC 508.4
  
 3) PLEASE SHOW THE FIRE RATING OF THE STAIR ENCLOSURE
 1011.7.3 ENCLOSURES UNDER INTERIOR STAIRWAYS.
 THE WALLS AND SOFFITS WITHIN ENCLOSED USABLE SPACES
 UNDER ENCLOSED AND UNENCLOSED STAIRWAYS SHALL BE
 PROTECTED BY 1-HOUR FIRE-RESISTANCE-RATED CONSTRUCTION
 OR THE FIRE-RESISTANCE RATING OF THE STAIRWAY
 ENCLOSURE, WHICHEVER IS GREATER. ACCESS TO THE ENCLOSED
 SPACE SHALL NOT BE DIRECTLY FROM WITHIN THE STAIRWAY
 ENCLOSURE.
  
 4) ACCESSIBLE RESTROOM - ON DRAWING A3.0 - PLEASE SHOW
 THE TOILET PAPER HOLDER DIMENSION FROM THE FRONT OF THE
 TOILET TO THE CENTER OF THE DISPENSER (NOT TO THE SIDE
 AS SHOWN)- FBC A 604.7 DISPENSERS.
 TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND
 SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230
 MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO
 THE CENTERLINE OF THE DISPENSER.
  
 5) ACCESSIBLE RESTROOM - ON DRAWING A3.0 - PLEASE SHOW
 THE TOILET REAR GRAB BAR LOCATION DIMENSIONS FROM THE
 CENTER OF THE TOILET (NOT FROM THE SIDE WALL AS SHOWN)
 PER FBC A 604.5.2 REAR WALL.
 THE REAR WALL GRAB BAR SHALL BE 36 INCHES (915 MM) LONG
 MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER
 CLOSET 12 INCHES (305 MM) MINIMUM ON ONE SIDE AND 24
 INCHES (610 MM) MINIMUM ON THE OTHER SIDE.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved