| Plan Review Notes For Permit 23040432 |
| Permit Number |
23040432 |
|
| Review Stop |
G |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2023-04-12 15:34:08 | 1ST REVIEW FBC-2020 RES. GAS | | | PERMIT- 23040432 | | | 4/12/2023 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) A COMPLETE GAS RISER IS REQUIRED WHICH INCLUDES THE | | | PREVIOUS GAS PIPING AND APPLIANCE INSTALLED UNDER | | | PERMIT 00050753- SEC. G2412.3 & G2412.4 FBC RES. THE | | | APPROVED RISER UNDER 00050753 SHOWS A 1-INCH GALVANIZED | | | PIPE AT THE METER SUPPLYING INTERIOR GAS APPLIANCES- | | | DRYER (35,000 BTU), WATER HEATER (55,000), AND RANGE | | | (40,000). THE TOTAL DEVELOPED LENGTH OF THE PIPE RUN | | | SHOWN IS APPROXIMATELY 60 FT. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|