| 2023-05-08 11:23:14 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | | APPROVAL FL16709-R10 SELECTED OPTION FOR SYSTEM NO W-5; | | | EXPOSURE (B); ENCLOSURE (OPEN); ROOF HEIGHT H < 15; | | | ULTIMATE WIND SPEED (150), IS NOT CORRECT. THE CORRECT | | | EXPOSURE FOR THE LISTED ADDRESS IS EXPOSURE C; THE | | | CORRECT ENCLOSURE IS (ENCLOSED); THE CORRECT ROOF | | | HEIGHT IS 15 < H < 20. WIND SPEED 170. PLEASE SELECT | | | THE CORRECT OPTIONS INCLUDING CORRECT FASTENING | | | PATTERNS FOR ZONE 1 PRIME, ZONES 1, 2 & 3. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|