Plan Review Notes
Plan Review Notes For Permit 23031754
Permit Number 23031754
Review Stop B
Sequence Number 1
Notes
Date Text
2023-04-06 18:27:28RESIDENTIAL (R3) BUILDING REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #23031754
 369 ORANGE WAY
  
 1-THE GENERATOR SHALL BE LOCATED A MINIMUM OF 10 FT.
 FROM ANY OPENING INCLUDING WINDOWS, DOORS, ETC. SEC.
 R303.5.1 FBC RES. REVISE NOTE ON SURVEY INDICATING 5
 FT.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]