| 2023-03-28 07:13:10 | 2ND PLUMBING REVIEW | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. 2017 WPB AMEND 107.3.5.3 (13) - INCLUDE A FLOOR PLAN | | | AND SHOW WHERE THE DRYER AND WATER HEATER ARE LOCATED. | | | MAKE SURE THE FLOOR PLAN INCLUDES: | | | A) FOR THE DRYER, SHOW THE ROOM SIZE IT IS LOCATED IN | | | AND INCLUDE THE COMBUSTION AIR/MAKE UP AIR CALCULATIONS | | | REQUIRED BY 2020 FRC G2407.1 | | | B) FOR THE WATER HEATER, SHOW THAT IT WILL BE SEPARATED | | | FROM ANY "4 FEET (1219 MM) BELOW, 4 FEET (1219 MM) | | | HORIZONTALLY FROM, OR 1 FOOT (305 MM) ABOVEDOOR, | | | OPERABLE WINDOW OR GRAVITY AIR INLET INTO ANY BUILDING" | | | PER 2020 FRC G2427.8. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | | | | |
|