| Plan Review Notes For Permit 23030724 |
| Permit Number |
23030724 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2023-03-22 13:15:41 | REVISION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) PLEASE SHOW THE EXTERIOR LANDING FOR THE ADDED DOOR | | | TO COMPLY WITH - FBC 1010.1.5 FLOOR ELEVATION. | | | THERE SHALL BE A FLOOR OR LANDING ON EACH SIDE OF A | | | DOOR. SUCH FLOOR OR LANDING SHALL BE AT THE SAME | | | ELEVATION ON EACH SIDE OF THE DOOR. LANDINGS SHALL BE | | | LEVEL EXCEPT FOR EXTERIOR LANDINGS, WHICH ARE PERMITTED | | | TO HAVE A SLOPE NOT TO EXCEED 0.25 UNIT VERTICAL IN 12 | | | UNITS HORIZONTAL (2-PERCENT SLOPE). | | | | | | FBC 1010.1.6 LANDINGS AT DOORS. | | | LANDINGS SHALL HAVE A WIDTH NOT LESS THAN THE WIDTH OF | | | THE STAIRWAY OR THE DOOR, WHICHEVER IS GREATER. DOORS | | | IN THE FULLY OPEN POSITION SHALL NOT REDUCE A REQUIRED | | | DIMENSION BY MORE THAN 7 INCHES (178 MM). WHERE A | | | LANDING SERVES AN OCCUPANT LOAD OF 50 OR MORE, DOORS IN | | | ANY POSITION SHALL NOT REDUCE THE LANDING TO LESS THAN | | | ONE-HALF ITS REQUIRED WIDTH. LANDINGS SHALL HAVE A | | | LENGTH MEASURED IN THE DIRECTION OF TRAVEL OF NOT LESS | | | THAN 44 INCHES (1118 MM). | | | | | | 2) PLEASE PROVIDE A SURVEY SHOWING THE PROPERTY LINES - | | | FBC 3202.2 DOORS AND WINDOWS SHALL NOT OPEN OR PROJECT | | | INTO THE PUBLIC RIGHT-OF-WAY. |
|