Date Text
2023-05-03 15:41:413RD NFIP REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 CITY ORDINANCE NO. 4658-16 AND NO. 4729-17
 FEMA DESK REFERENCE P 758
 FBC R322 FLOOD-RESISTANT CONSTRUCTION
  
 NOTICE: THIS PROJECT IS LOCATED IN A SPECIAL FLOOD
 HAZARD AREA (SFHA). THE FLOOD ZONE DESIGNATIONS FOR
 THIS SITE ARE AE 6 AND AE 7 WITH A BASE FLOOD
 ELEVATIONS (BFE) OF 6'0" AND 7'0" NAVD.
 THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE NO.
 4729-17) REQUIRES AN ADDITIONAL 24 INCHES OF FREEBOARD.
 THE DESIGN FLOOD ELEVATION (DFE) SHALL BE AT OR ABOVE
 9'0" NAVD.
  
 CITY OF WEST PALM BEACH, FLORIDA ORDINANCE NO. 4729-17
 SECTION 4: THE CODE OF ORDINANCES IS HEREBY AMENDED AT
 CHAPTER 18, BUILDINGS AND BUILDING REGULATIONS, ARTICLE
 II, BUILDING CODE, TO ADD SECTION 18-33, TECHNICAL
 AMENDMENTS TO FLORIDA BUILDING CODE, RESIDENTIAL, WHICH
 SHALL READ AS FOLLOWS:
 SEC. 18-33 - TECHNICAL AMENDMENTS TO FLORIDA BUILDING
 CODE, RESIDENTIAL.
 R322.2.1 ELEVATION REQUIREMENTS.
 1.BUILDINGS AND STRUCTURES IN FLOOD HAZARD AREAS NOT
 DESIGNATED AS COASTAL A ZONES SHALL HAVE THE LOWEST
 FLOORS ELEVATED TO OR ABOVE THE BASE FLOOD ELEVATION
 PLUS ONE FOOT, OR THE DESIGN FLOOD ELEVATION, WHICHEVER
 IS HIGHER. (PLUS TWO FEET PER CITY ORDINANCE 4729-17).
  
  
 CONSTRUCTION DRAWING ELEVATION CERTIFICATE:
  
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT:
  
 1. LINE A3 - THE DATA ENTERED IS NOT COMPREHENSIVE. THE
 PREFERRED DATA IS THE PCN # 74434403140000020
 2. LINES A8 B) & C) SHOULD BE N/A PER EC INSTRUCTIONS.
 3. LINES A9 B) & C) SHOULD BE N/A PER EC INSTRUCTIONS.
 4. LINE C2 F) PLEASE REVIEW THIS DATA. THE EROSION
 CONTROL PLAN INDICATES THE LAG IS 4.0'.
 5. LINE C2 G) PLEASE REVIEW THIS DATA. THE EROSION
 CONTROL PLAN INDICATES THE HAG IS 7.0'.
 6. LINE C2 H) PLEASE REVIEW THIS DATA. THE EROSION
 CONTROL PLAN INDICATES THE LAG IS 4.0'.
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  